Поставка оптоэлектронных компонентов ведущих мировых производителей

Набор для тестирования Agilent N1015A

N1015A — это тестовый набор от Agilent. Набор для тестирования электронного оборудования — это инструмент, который инженеры используют для простой и точной характеристики радиочастотных компонентов. Эти тестовые наборы представляют собой устройства, которые позволяют измерять важные электронные параметры, четко отображая их на легко читаемых определенных дисплеях.

Артикул: N1015A Agilent Test Set
Options305
20 MHz Modulator

Additional Features:

  • Modulation Test Set for the 71501D
  • Power: 115 VAC: 50 VA MAX, 230 VAC: 70 VA MAX.
  • Voltage: nominal: 115 VAC/230 VAC, range 115 VAC: 90–132 V, range 230 VAC: 198–254 V
  • Frequency: nominals: 50 Hz / 60 Hz, range: 47–63 Hz
  • Temperature: Operating 0°C to +55°C, Non-operating –40°C to +70°C
  • Maximum Relative Humidity: 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
  • Altitude: Operating: Up to 5,600 meters (15,000 ft.), Non-operating: Up to 5,600 meters (15,000 ft.)
  • Dimensions: Height 88 mm, Width 425 mm, Depth 498 mm

The Agilent N1015A modulation test set enables the expanded modulation bandwidths to 20 and 80 MHz at 2.5 and 10 Gb/s respectively. It also enables the 0.002 UI rms intrinsic jitter noise floor. Although the system is frequency agile, the 20 MHz expanded modulation range is limited to between 2.4 and 3.2 Gb/s. The 80 MHz expanded modulation range is limited to between 9.8 and 12.5 Gb/s.

Because the system is completely frequency agile, these tests can also be performed at any rate from below 50 Mb/s to above 12.5 Gb/s, such as the Fibre Channel 1063 Mb/s rate. Some utility for the STM-1/OC-3 (155 Mb/s) rate may be obtained. For 622 Mb/s (STM-4/OC-12) or 155 Mb/s (STM-1/OC-3), the Agilent N1015A modulation test set is not necessary for SDH/SONET standards tests.

The Agilent N1015A modulation test set allows STM-16/OC-48 (2488 Mb/s) and STM-64/OC-192 (9953Mb/s) compliant jitter measurements by providing an 80MHz modulation bandwidth and 0.002 UI rms intrinsic jitter noise floor. The signal is routed to the Agilent 86130A or 71612C pattern generator, thus producing data with the desired jitter. This data signal is then fed to the DUT. The recovered clock signal is routed to Channel 1 of the Agilent 71501D. The clock signal from the pattern generator is used as a reference signal and is routed to Channel 2 of the 71501D. Jitter transfer measurement accuracy is enhanced if signal harmonic content is suppressed. Thus low pass or band-pass filters are typically used in the measurement paths. The results of the jitter transfer measurement can be displayed in one of three ways: «Transfer Plot», «Delta Plot» and «Numerical Listing».

Технические характеристики

ManufacturerAgilent, HP, Keysight
ConditionUsed

N1015A Agilent Test Set Набор для тестирования Agilent N1015A — товар из ассортимента Laserzz для подбора и поставки под задачи ремонта и комплектации.

Позиция подходит для сценариев замены и закупки под конкретную спецификацию оборудования.

Для корректного выбора сверяйте маркировку, параметры и совместимость с вашей схемой/узлом.

Вопросы и ответы

Как проверить совместимость товара?

Сравните артикул, технические параметры и формат исполнения с требованиями вашей модели оборудования.

Можно ли заказать партию?

Да, для партийных закупок доступны отдельные условия, ориентируйтесь на количество и сроки поставки.