Magnetic level gauges with electrical contact and thermostat (optional pt100) threaded 1 ‘BSP or Flanged SPST or SPDT contacts USE: Made to ensure the minimum or maximum level in tanks and hydraulic power packs and activation of the thermostat when, for operating reasons, the temperature must not exceed values harmful to correct operation. LEVEL INDICATOR OPERATION: When the float of the indicator encounters the Reed switch at the pre-established point, the contact activated by the magnet housed in the float opens or closes, thus obtaining the possibility of sending a luminous or acoustic signal or activating or disconnecting any electrical equipment connected to it. THERMOSTAT OPERATION: When the temperature of the liquid in the tank reaches the thermostat setting value, the thermostat closes or opens for switching on a lamp or interrupting operation of the machine connected to it, or activating any cooling equipment, thus preventing the risk of overheating and permanent damage. FITTING: The indicator must be fitted in the vertical position. The float must be at least 35mm from ferrous surfaces (tank walls, etc.). IMPORTANT: To invert the level signal from N.C. to N.O. and vice versa, just remove the bottom stop and turn the float upside down.
Технические характеристики
CharacteristicsTechnologymagnetic floatMediumfor liquidsApplicationsfor tanksMaterialbrassMountingvertical, threaded, flangeOther characteristicsreed switch, single-point, with temperature switch, IP65Process temperature
Max.: 120 °C (248 °F)
Min.: -20 °C (-4 °F)
Process pressure
Max.: 10 bar (145.04 psi)
Min.: 0 bar (0 psi)