Description
The PosiTector 6000 is a rugged coating thickness gage that uses magnetic and eddy current ideals to easily and precisely measure both ferrous and non-ferrous metals. For most applications, the PosiTector 6000 is ready to measure without any calibration adjustments. These gages are weatherproof — resistant to oil, water, dust, acid, and solvent. The interchangeable platform also allows for any PosiTector probe to attach to a single gage body. Extended cables, up to 75 m (250 ft), are available for remote or underwater measuring.
The PosiTector 6000 has USB, WiFi, and Bluetooth connectivity for PosiSoftware, PC and Mac, and Smartphones. PosiTector 6000 gages have two body options, standard and advanced. Standard models can store or download up to 1000 readings per probe and Advanced models can store or download up to 250,000 readings in up to 1,000 batches and sub-batches. The Advanced Model can also show live graphing of measurement data.
Технические характеристики
Specs
Ferrous | Model | DeFelsko Coating Thickness Standards | Probe Style | Range | Accuracy |
FT1/FT3 | STDP1 | Integral | 0-250 mils | ±,(0.05 mils +1%) 0-100 mils | |
F1/F3 | STDS1 STDA1 | 0-60 mils 0-1500 &mu,m | ±,(0.05 mils +1%) 0-2 mils | ||
FS1/FS3 | STDS1 STDA1 | Regular Cabled | 0-60 mils 0-1500 &mu,m | ||
FXS1/FXS3 | STDS4 | 0-80 mils 0-2000 &mu,m | |||
FRS1/FRS3 | STDS1 STDA1 | 90 Regular Cabled | 0-60 mils 0-1500 &mu,m | ||
F0S1/F0S3 | STDS2 STDA2 | 0 Microprobe | 0-45 mils 0-1150 &mu,m | ±,(0.02 mils +1%) 0-4 mils | |
F45S1/F45S3 | STDS2 STDA2 | 45 Microprobe | 0-45 mils 0-1150 &mu,m | ||
F90S1/F90S3 | STDS2 STDA2 | 90 Microprobe | 0-45 mils 0-1150 &mu,m | ||
F90ES1/F90ES3 | STDS2 STDA2 | 90 Extended Microprobe | 0-45 mils 0-1150 &mu,m | ||
FTRS1/FTRS3 | STDP1 | 90 High-Range Cabled | 0-250 mils 0-6 mm | ±,(0.05 mils +1%) 0-100 mils ±,(0.5 mils + 3%) >, 100 mils | |
FTS1/FTS3 | STDP1 | High-Range Cabled | 0-250 mils 0-6 mm | ||
FHXS1/FHXS3 | STDP7 | 0-400 mils 0-10000 &mu,m | ±,(0.1 mils + 3%) ±,(2 &mu,m +3%) | ||
FKS1/FKS3 | STDP5 | 0-500 mils 0-13 mm | ±,(1 mils + 3%) 0-500 mils ±,(0.02 mm +3%) 0-13 mm | ||
FJS1/FJS3 | STDP2 | 0-24 mm 0-1.0 | ±,(0.1 mils + 3%) ±,(0.2 &mu,m +3%) | ||
FLS1/FLS3 | STDP8 | 0-8 mm 0-1.5 | ±,(0.01 mils + 3%) ±,(0.2 &mu,m +3%) |
Non-Ferrous | Model | DeFelsko Coating Thickness Standards | Probe Style | Range | Accuracy |
N1/N3 | STDS1 STDA1 | Integral | 0-60 mils 0-1500 &mu,m | ±,(0.05 mils +1%) 0-2 mils | |
NS1/NS3 | STDS1 STDA1 | Regular Cabled | 0-60 mils 0-1500 &mu,m | ||
NAS1/NAS3 | STDS2 | 0-25 mils | |||
NRS1/NRS3 | STDS1 | 90 Regular Cabled | 0-60 mils | ||
N0S1/N0S3 | STDS2 | 0 Microprobe | 0-25 mils | ±,(0.02 mils +1%) 0-4 mils | |
N45S1/N45S3 | STDS2 STDA2 | 45 Microprobe | 0-25 mils 0-625 &mu,m | ||
N90S1/N90S3 | STDS2 | 90 Microprobe | 0-25 mils | ||
NKS1/NKS3 | STDP5 | High-Range Cabled | 0-500 mils 0-13 mm | ±,(1 mils + 3%) 0-500 mils ±,(0.02 mm +3%) 0-13 mm |
Ferrous/Non-Ferrous | Model | DeFelsko Coating Thickness Standards | Probe Style | Range | Accuracy |
FN1/FN3 | STDS1 STDA1 | Integral | 0-60 mils 0-1500 &mu,m | ±,(0.05 mils +1%) 0-2 mils | |
FNS1/FNS3 | STDS1 | Regular Cabled | 0-60 mils | ||
FNDS1/FNDS3 | STDS1 | 0-60 mils | Paint Layer: | ||
FNRS1/FNRS3 | STDS1 | 90 Regular Cabled | 0-60 mils | ±,(0.05 mils +1%) 0-2 mils | |
FNTS1/FNTS3 | STDP1 | High-Range Cabled | 0-250 mils | ±,(0.05 mils +1%) 0-100 mils | |
FNGS1/FNGS3 | STDP8 | 0-63.5 mm | ±,(0.01 in + 3%) |