Specification:
| Part Number: 1207798 |
| Maximum demand rate: 34 /min (EN ISO 13849) |
| Permitted cable length: ≤ 20 m |
| Safe state in the event of a fault: At least one OSSD is in the OFF state. |
| Performance level: PL c (EN ISO 13849), Pay attention to optical characteristics! |
| Protection class: III (EN 61140) |
| Switching voltage LOW: 2 V DC |
| Weight: 155 g |
| Protective field height: 420 mm |
| Switching voltage HIGH: 24 V DC (VS — 2.25 V DC … VS) |
| Switching current: 300 mA |
| Enclosure rating: IP 65 (EN 60529) |
| Resolution: 14 mm |
| Synchronization: Optical, without separate synchronization |
| Integration via Flexi Soft safety controller: CANopen, DeviceNet, EtherCAT, EtherNet/IP, Modbus TCP, PROFIBUS DP, PROFINET |
| Restart interlock (delivery status): Deactivated |
| Scanning range: 0 m … 6 m |
| Ripple: ≤ 10 % |
| Beam coding: + |
| Safe SICK device communication via EFI/SDL: — |
| Housing cross-section (incl. system connection): 15 mm x 32 mm |
| Supply voltage: 24 V DC (19.2 V DC … 28.8 V DC) |
| Housing material: Aluminum alloy ALMGSI 0.5 |
| Vibration resistance: 5 g, 10 Hz … 55 Hz (EN 60068-2-6) |
| TM (mission time): 20 a (EN ISO 13849) |
| Typical range: 0 m … 8 m |
| PFHd: Standalone system: 2.4 1E-08 (EN ISO 13849) |
| Ambient operating temperature: -20 °C … +55 °C |
| Category: Category 2 (EN ISO 13849) |
| Power consumption: ≤ 3 A |
| Type: Type 2 (IEC 61496) |
| Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored |
| Restart interlock: + |
| Shock resistance: 10 g, 16 ms (EN 60068-2-27) |
| External device monitoring (delivery status): Deactivated |
| External device monitoring (EDM): + |
| Display elements: LEDs |
| Response time: ≤ 14 ms |
| Configuration method: Hard wired |
| Test rate (internal test): 58 /s |
| Automatic beam coding: + |
| Connection type: Male connector M12, 5-pin |
| Cascaded: — |
| Conductor cross-section: 0.34 mm? |
| Air humidity: 15 % … 95 %, non-condensing |
| Storage temperature: -25 °C … +70 °C |
| Cable length: 350 mm |
| Safety integrity level: SIL1 (IEC 61508), SILCL1 (EN 62061) |