Specification:
| Part Number | 1207871 |
| Safe state in the event of a fault: | At least one OSSD is in the OFF state. |
| Cable length: | 350 mm |
| Weight: | 155 g |
| Enclosure rating: | IP 65 (EN 60529) |
| Housing material: | Aluminum alloy ALMGSI 0.5 |
| Connection type: | Male connector M12, 5-pin |
| Protection class: | III (EN 61140) |
| TM (mission time): | 20 a (EN ISO 13849) |
| Power consumption: | ≤ 3 A |
| Resolution: | 14 mm |
| Display elements: | LEDs |
| Conductor cross-section: | 0.34 mm? |
| Storage temperature: | -25 °C … +70 °C |
| Scanning range: | 0 m … 6 m |
| Type: | Type 2 (IEC 61496) |
| Restart interlock (delivery status): | Deactivated |
| Configuration method: | Hard wired |
| Maximum demand rate: | 28 /min (EN ISO 13849) |
| Cascaded: | + |
| Test rate (internal test): | 47 /s |
| Automatic beam coding: | + |
| External device monitoring (EDM): | + |
| Typical range: | 0 m … 8 m |
| Ripple: | ≤ 10 % |
| Ambient operating temperature: | -20 °C … +55 °C |
| Supply voltage: | 24 V DC (19.2 V DC … 28.8 V DC) |
| Switching current: | 300 mA |
| Safe SICK device communication via EFI/SDL: | — |
| Vibration resistance: | 5 g, 10 Hz … 55 Hz (EN 60068-2-6) |
| Beam coding: | + |
| Response time: | ≤ 14 ms |
| Air humidity: | 15 % … 95 %, non-condensing |
| Protective field height: | 420 mm |
| Restart interlock: | + |
| Shock resistance: | 10 g, 16 ms (EN 60068-2-27) |
| Integration via Flexi Soft safety controller: | CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET |
| Performance level: | PL c (EN ISO 13849), Pay attention to optical characteristics! |
| PFHd: | Cascaded systems: 5.2 1E-08 (EN ISO 13849) |
| Type of output: | PNP semiconductors, short-circuit protected, cross-circuit monitored |
| Housing cross-section (incl. system connection): | 15 mm x 32 mm |
| Switching voltage HIGH: | 24 V DC (VS — 2.25 V DC … VS) |
| External device monitoring (delivery status): | Deactivated |
| Permitted cable length: | ≤ 20 m |
| Synchronization: | Optical, without separate synchronization |
| Connection type extension connection: | Female connector M12, 5-pin |
| Safety integrity level: | SIL1 (IEC 61508) SILCL1 (EN 62061) |
| Category: | Category 2 (EN ISO 13849) |
| Switching voltage LOW: | 2 V DC |
This device has a part number 1207871. In case of a fault, the safe state is when at least one OSSD is in the OFF state. The cable length is 350 mm and the weight is 155 g. The enclosure rating is IP 65 according to EN 60529.
The housing material is aluminum alloy ALMGSI 0.5. The connection type is a male M12 connector with 5 pins. The protection class is III (EN 61140). The TM (mission time) is 20 a (EN ISO 13849). The power consumption is ≤ 3 A, and the resolution is 14 mm. Display elements are LEDs. The conductor cross-section is 0.34 mm².
The storage temperature ranges from -25 °C to +70 °C. The scanning range is from 0 m to 6 m. The type is Type 2 (IEC 61496). The restart interlock is deactivated by default. The configuration method is hard wired. The maximum demand rate is 28 /min (EN ISO 13849). The device supports cascading (+). The test rate (internal test) is 47 /s. Automatic beam coding (+) and external device monitoring (EDM) (+) are supported. The typical range is from 0 m to 8 m. Ripple is ≤ 10 %. The ambient operating temperature is from -20 °C to +55 °C. The supply voltage is 24 V DC (19.2 V DC … 28.8 V DC). The switching current is 300 mA. Safe SICK device communication via EFI/SDL is not supported (-). Vibration resistance is 5 g, 10 Hz … 55 Hz (EN 60068-2-6). Beam coding is supported (+). Response time is ≤ 14 ms. Air humidity is 15 % … 95 %, non-condensing. The protective field height is 420 mm. Restart interlock is supported (+). Shock resistance is 10 g, 16 ms (EN 60068-2-27). Integration is possible via Flexi Soft safety controller, supporting CANopen, DeviceNet, EtherCAT, EtherNet/IP, Modbus TCP, PROFIBUS DP, PROFINET. The performance level is PL c (EN ISO 13849), with attention to optical characteristics. PFHd for cascaded systems is 5.2 1E-08 (EN ISO 13849). The type of output is PNP semiconductors, short-circuit protected, cross-circuit monitored. The housing cross-section (incl. system connection) is 15 mm x 32 mm. Switching voltage HIGH is 24 V DC (VS — 2.25 V DC … VS). The external device monitoring (delivery status) is deactivated. The permitted cable length is ≤ 20 m. Synchronization is optical, without separate synchronization. The connection type for extension connection is a female M12 connector with 5 pins. Safety integrity level is SIL1 (IEC 61508) and SILCL1 (EN 62061). Switching voltage LOW is 2 V DC.