Specification:
| Part Number | 1207925 |
| Type of output: | PNP semiconductors, short-circuit protected, cross-circuit monitored |
| Ambient operating temperature: | -20 °C … +55 °C |
| Shock resistance: | 10 g, 16 ms (EN 60068-2-27) |
| Safety integrity level: | SIL1 (IEC 61508) SILCL1 (EN 62061) |
| Category: | Category 2 (EN ISO 13849) |
| PFHd: | Standalone system: 2.4 1E-08 (EN ISO 13849) |
| Safe SICK device communication via EFI/SDL: | — |
| Synchronization: | Optical, without separate synchronization |
| External device monitoring (EDM): | + |
| Cable length: | 350 mm |
| Maximum demand rate: | 34 /min (EN ISO 13849) |
| Typical range: | 0 m … 8 m |
| Switching current: | 300 mA |
| Housing material: | Aluminum alloy ALMGSI 0.5 |
| Restart interlock (delivery status): | Deactivated |
| Switching voltage HIGH: | 24 V DC (VS — 2.25 V DC … VS) |
| Connection type: | Male connector M12, 5-pin |
| Test rate (internal test): | 58 /s |
| Scanning range: | 0 m … 6 m |
| Performance level: | PL c (EN ISO 13849), Pay attention to optical characteristics! |
| Storage temperature: | -25 °C … +70 °C |
| Automatic beam coding: | + |
| Conductor cross-section: | 0.34 mm? |
| TM (mission time): | 20 a (EN ISO 13849) |
| Housing cross-section (incl. system connection): | 15 mm x 32 mm |
| External device monitoring (delivery status): | Deactivated |
| Supply voltage: | 24 V DC (19.2 V DC … 28.8 V DC) |
| Safe state in the event of a fault: | At least one OSSD is in the OFF state. |
| Integration via Flexi Soft safety controller: | CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET |
| Cascaded: | — |
| Weight: | 95 g |
| Protection class: | III (EN 61140) |
| Power consumption: | ≤ 3 A |
| Air humidity: | 15 % … 95 %, non-condensing |
| Restart interlock: | + |
| Protective field height: | 240 mm |
| Beam coding: | + |
| Switching voltage LOW: | 2 V DC |
| Display elements: | LEDs |
| Response time: | ≤ 14 ms |
| Resolution: | 14 mm |
| Ripple: | ≤ 10 % |
| Vibration resistance: | 5 g, 10 Hz … 55 Hz (EN 60068-2-6) |
| Permitted cable length: | ≤ 20 m |
| Enclosure rating: | IP 65 (EN 60529) |
| Type: | Type 2 (IEC 61496) |
| Configuration method: | Hard wired |
The product has a part number 1207925. The output type is PNP semiconductors with short-circuit and cross-circuit monitoring. The ambient operating temperature ranges from -20 °C to +55 °C. The device has a shock resistance of 10 g (16 ms, EN 60068-2-27) and vibration resistance of 5 g (10 Hz to 55 Hz, EN 60068-2-6).
It meets safety integrity level SIL1 (IEC 61508) and SILCL1 (EN 62061), with a category of 2 according to EN ISO 13849. The PFHd for a standalone system is 2.4 x 1E-08 (EN ISO 13849). Communication via EFI/SDL is not supported (-). Synchronization is optical without separate synchronization. External device monitoring (EDM) is enabled (+).
The cable length is 350 mm. The maximum demand rate is 34 per minute (EN ISO 13849). The typical range is 0 m to 8 m, and the scanning range is 0 m to 6 m. The switching current is 300 mA. The housing material is Aluminum alloy ALMGSI 0.5. The restart interlock is deactivated by default.
Switching voltage HIGH is 24 V DC (VS — 2.25 V DC to VS). The connection type is a male M12 connector with 5 pins. The internal test rate is 58 Hz. The performance level is PL c (EN ISO 13849), with a note about optical characteristics. The storage temperature is -25 °C to +70 °C. Automatic beam coding is enabled (+).
Conductor cross-section is 0.34 mm². The mission time (TM) is 20 years (EN ISO 13849). The housing cross-section, including system connection, is 15 mm x 32 mm. External device monitoring (delivery status) is deactivated. The supply voltage is 24 V DC (19.2 V DC to 28.8 V DC). The safe state in case of a fault is that at least one OSSD is in the OFF state.
Integration via Flexi Soft safety controller supports CANopen, DeviceNet, EtherCAT, EtherNet/IP, Modbus TCP, PROFIBUS DP, and PROFINET. Cascaded operation is not supported (-). The weight is 95 g. Protection class is III (EN 61140). Power consumption is ≤ 3 A. Air humidity is 15% to 95% (non-condensing).
Restart interlock is enabled (+). The protective field height is 240 mm. Beam coding is enabled (+). Switching voltage LOW is 2 V DC. Display elements are LEDs. The response time is ≤ 14 ms. Resolution is 14 mm. Ripple is ≤ 10 %. The permitted cable length is ≤ 20 m. Enclosure rating is IP 65 (EN 60529). Type is Type 2 (IEC 61496). Configuration method is hard wired.