Поставка оптоэлектронных компонентов ведущих мировых производителей

Высокоэффективный жидкостный хроматограф Beckman System Gold

Доставка импортных компонентов по России от 3х недель транспортными компаниями СДЭК, Деловые Линии, Major Express.
Оплата физическими и юридическими лицами безналичным расчетом.
Цена может измениться после запроса у поставщика!
Артикул: 8043-30-1079 TME арт.: 8043-30-1079

Product Description 10mm stainless steel 17ul capacity flow cell Programmable functions: wavelength range rise time auto zero etc. Wavelength range: 190 700 nm single channel programmable Wavelength accuracy: +/- 2 nm after calibration Beckman System Gold High Performance Liquid Chromatograph Overview Beckman System Gold(R) HPLC systems incorporate the latest technological advances in hardware design. The solvent delivery modules are built with the digitally controlled rapid refill pump design with automatic compressibility compensation that has received multiple patents. These features produce smooth flow from microbore to semi-preparative flow rates and the high-pressure mixing design eliminates the need for constant helium sparging or degassing. The pumps are combined with high-sensitivity UV/VIS and diode array detectors and autosamplers with automation capability to build HPLC systems that have a reputation for the best performance ease of use and troubleshooting and longevity due to a solid and reliable design&hellip,simply put you cant go wrong with GOLD! Beckman Gold that is&hellip, Current Beckman System Gold HPLC in-stock configuration is UV-VIS Detector model 166 Solvent delivery module [pump] model 125S Fraction collector optional Model 508 autosampler Computer workstation with CPU Monitor and printer 32-Karat software version 3.0 Beckman System Gold HPLC Model 166 detector features 10mm stainless steel 17ul capacity flow cell Programmable functions: wavelength range rise time auto zero event mark relays lamp off peak detection peak threshold audible alarms bandwidth and stop data. Wavelength range: 190 700 nm single channel programmable requires Tungsten lamp for visible light Wavelength accuracy: +/- 2 nm after calibration Wavelength repeatability: +/- 0.05 nm Bandwidth: &lt, 5nm @ 254 Linearity *Analytical flow cell: +/- 1% from 0.1 to1.0 AU t0 +/-0.001 AU below 0.1 AU +/- 5% from 1.0 to 1.5 AU Noise *Analytical flow cell: Drift *Analytical flow cell: less than 0.0001AU/hr at constant temperature Rise time: selectable 1 5 seconds Detector: double-beam grating monochromator dual photodiode sensor Light source: UV-pre-aligned D2 lamp 190 360 or 361 700nm visible-optional tungsten lamp 361 700nm Memory protection: battery back up maintains parameters for 1 week Beckman System Gold HPLC Model 125 solvent delivery module (pump) features Flow range: 0.01 10.0 ml/mi for each pumping mechanism 0.1 mL increments, max flow rate 10mL/min Preparativ, 0.03 to 30.0 mL/min with optional preparative liquid head for each pumping mechanism. Max iscoratic flow rate 30 mL/min Reproducability: +/- 1% or 0.003 mL/min. whichever is greater Composition range: 0-100% in 0.01 increments Operating pressure: 0-6000 p.s.i. Operating temp: 4 40 degreesC Maximum solvent temp: 75C Piston displacement: 90ul prepartive 243uL Program functions: flow gradient curve composition external contacts audible alarm High Pressure Limit: Selectable 20-6500 psi Low Pressure Limit: Selectabl 0-6490 psi Beckman System Gold HPLC configurations Pumps: 118 125 126 127 128 Detectors: 166 uv vis 168 diode array Autosampler: 507 or 508

Технические характеристики