Система биоочистки KNAUER для аффинной хроматографии до 50 мл/мин

Доставка импортных компонентов Knauer по России от 3х недель транспортными компаниями СДЭК, Деловые Линии, Major Express.
Оплата физическими и юридическими лицами безналичным расчетом.
Цена может измениться после запроса у поставщика!

Product Description KNAUER Bio Purification System for Affinity Chromatography Automatic inlet valve for up to 8 buffers or samples Outlet valve (16 ports) for fractionation Flow rate: 0.01 50 ml/min, 1 40 ml/min (recommended) Variable single wavelength UV-detector (190 500 nm) Columns from all venders can be used Purity Chrom software Maximum system pressure: 50 bar 2-Year Factory Warranty #gap-1323065353 { padding-top: 30px, } The AZURA Bio compact AC system qualifies for fast and reliable affinity chromatography. The system offers outstanding performance and ease of use thanks to its compact design and user-friendly FPLC software PurityChrom. Select your sample, your washing and elution buffer using the inlet valve. Your proteins of interest are detected by UV and automatically collected via the fractionation valve. Pre-designed methods and cleaning steps are included in the software and can be easily adapted by changing the column volume. #image_1555704787 { width: 60%, } Key Features Automatic inlet valve for up to 8 buffers or samples Outlet valve (16 ports) for fractionation Flow rate: 0.01 50 ml/min, 1 40 ml/min (recommended) Variable single wavelength UV-detector (190 500 nm) Columns from all venders can be used Purity Chrom software Maximum system pressure: 50 bar #gap-1672461479 { padding-top: 30px, } Download System Proposal #col-784109938 > .col-inner { margin: 0px 0px -14px 0px, } Download KNAUER FPLC Brochure #col-445349221 > .col-inner { margin: 0px 0px -47px 0px, } My lab studies the structure and function of membrane proteins. Due to the inherent instability of these proteins we purify them in the cold room. We needed robust FPLCs with good pumps that tolerated these conditions well.In addition, the systems needed to be easy to maintain. Knauer provided us with skilled advice on virtually every component of the system, ranging from tubing and pumps up to the software. Consequently, our systems are perfectly tailored to our needs. Most of the maintenance we can do ourselves.For the remaining questions, we can rely on the great support Knauer offers. Our Knauer FPLCs are the no nonsense workhorses in the lab. I highly recommend Knauer. #text-1518517528 { font-size: 1rem, text-align: center, color: rgb(0,0,0), } #text-1518517528 > * { color: rgb(0,0,0), } #gap-1651947286 { padding-top: 26px, } #image_1757347093 { width: 32%, } Jun. Prof. Dr. Eric R. Geertsma Institute of Biochemistry, Goethe-University Frankfurt Let our team of experts help you find the perfect equipment for your application and budget, schedule a free meeting now: #text-1407968451 { font-size: 1rem, color: rgb(0,0,0), } #text-1407968451 > * { color: rgb(0,0,0), } Specifications #gap-40021395 { padding-top: 20px, } Purification simple, routine Application Affinity Chromatography Gradient No Flow rate Up To 50 ml/min #text-1156347527 { text-align: center, } #gap-2112978362 { padding-top: 18px, } #gap-1794769566 { padding-top: 7px, } #image_1859006880 { width: 100%, }

Технические характеристики