| Vibration resistance | 0.35 mm 10 … 57 Hz , 5 g 57 … 2000 Hz, 10 cycles |
| LED OUT | Switching state (output); LED yellow |
| Electrical safety | IEC 61140:2009 |
| Degree of protection | IP20 according to EN 60529 |
| Rated insulation voltage | 32 V |
| Note | This device is maintenance-free. If the device is used in a manner not specified by the manufaturer, the protection provided by the device may be impaired. |
| Number/Type | 2 safety-related inputs for mechanical contacts, crossed-circuit monitored: 2 single-channel contacts: Up to category 2/PLc in accordance with ISO 13849-1 or SIL 1 in accordance with IEC 62061 1 two-channel contact: Up to category 4/PLe in accordance with ISO 13849-1 or SIL 3 in accordance with IEC 62061 |
| LED IN | switching state (input); 2 LED yellow |
| UL approval | Protection class IP20 is not included in the UL approval. The protection class is tested by Pepperl+Fuchs. |
| Supply | from AS-Interface |
| ID2 code | 0 |
| Surge protection | Ue: Over voltage category III, safe isolated power supplies (PELV) |
| AS-Interface specification | V3.0 |
| Storage temperature | -25 … 85 ?°C (-13 … 185 ?°F) |
| Profile | S-7.B |
| ID code | B |
| Data bits (function via AS-Interface) | inputoutput |
| Mass | 28 g |
| Protection class | III |
| Shock and impact resistance | 30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks |
| Climatic conditions | For indoor use only |
| IO code | 7 |
| Fieldbus standard | EN 62026-2:2013 |
| ID1 code | F |
| UL File Number | E223772 |
| Rated operating current | ≤ 40 mA (without inputs/outputs)/max. 160 mA |
| Degree of protection | EN 60529:2000 |
| LED FAULT | error display; LED red red: communication error or address is 0 |
| Voltage | 20 … 30 V DC pulsed |
| Rated operating voltage | 26.5 … 31.6 V from AS-Interface (PELV) |
| Pollution degree | 2 |
| Pulse withstand voltage | 0.8 kV |
| Slave type | Safety-Slave |
| Altitude | ≤ 5000 m above MSL |
| Parameter bits (programmable via AS-i) | function |
| Emitted interference | EN 61000-6-4:2007 |
| Number/Type | 1 conventional electronic output, PNP , overload and short-circuit resistant |
| Noise immunity | IEC 62026-2:2013 EN 61326-3-1:2017 EN 61000-6-2:2005 |
| LED PWR | AS-Interface voltage; green LED green: voltage OK flashing green: address 0 |
| Relative humidity | 85 % , noncondensing |
| Current | ≤ 100 mA |
| Supply | from AS-Interface |
| Functional safety | EN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 |
| Connection | 200 mm, PVC cable 0.5 mm2 |
| AS-Interface | EN 62026-2:2013 |
| Voltage | (UASI — 7.0 V) ≤ UOUT ≤ UASI |
| Required master specification | ≥ V2.1 |
| Ambient temperature | -25 … 70 ?°C (-13 … 158 ?°F) |
| Current | input current limited ≤ 15 mA, short-circuit protected |