| General specifications | ||
| Switching element function | PNPNC | |
| Rated operating distance | 1.5 mm | |
| Installation | flush | |
| Output polarity | DC | |
| Assured operating distance | 0 … 1.215 mm | |
| Reduction factor rAl | 0.25 | |
| Reduction factor rCu | 0.2 | |
| Reduction factor r304 | 0.7 | |
| Nominal ratings | ||
| Operating voltage | 10 … 60 V | |
| Switching frequency | 0 … 500 Hz | |
| Reverse polarity protection | reverse polarity protected | |
| Short-circuit protection | pulsing | |
| Voltage drop | less than or equal to 3 V | |
| Operating current | 0 … 100 mA | |
| No-load supply current | less than or equal to 15 mA | |
| Switching state indicator | LED, yellow | |
| Functional safety related parameters | ||
| MTTFd | 2160 a | |
| Mission Time (TM) | 20 a | |
| Diagnostic Coverage (DC) | 0 % | |
| Approvals and certificates | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | Certified by China Compulsory Certification (CCC) | |
| Ambient conditions | ||
| Ambient temperature | -25 … 70 °C (-13 … 158 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | Stainless steel 1.4305 / AISI 303 | |
| Sensing face | PBT | |
| Housing diameter | 8 mm | |
| Degree of protection | IP67 | |
The assured operating distance ranges from 0 to 1.215 mm. The reduction factors are 0.25 for aluminum (rAl), 0.2 for copper (rCu), and 0.7 for 304 stainless steel (r304).
Nominal ratings include an operating voltage of 10 to 60 V and a switching frequency of 0 to 500 Hz. The sensor features reverse polarity protection and pulsing short-circuit protection. The voltage drop is a maximum of 3 V.
Operating current is between 0 and 100 mA. The no-load supply current is 15 mA or less. A yellow LED indicates the switching state.
Functional safety parameters include MTTFd of 2160 years, a mission time (TM) of 20 years, and diagnostic coverage (DC) of 0%.
Approvals and certificates include cULus Listed, General Purpose, cCSAus Listed, General Purpose, and CCC certification.
The ambient temperature range for this device is -25 to 70 °C. Mechanical specifications include a connector type of M12 x 1, 4-pin, housing material of Stainless steel 1.4305 / AISI 303, a PBT sensing face, and a housing diameter of 8 mm. The degree of protection is IP67.