Available from our partners!
| NO/NC programmable | ||
| Rated operating distance | 4 mm | |
| Installation | flush | |
| AS-Interface | ||
| 0 … 3.24 mm | ||
| Reduction factor rAl | 0.37 | |
| Reduction factor rCu | 0.36 | |
| Reduction factor r304 | 0.74 | |
| Slave type | Standard slave | |
| AS-Interface specification | V2.1 | |
| Required master specification | greater than or equal to V2.0 | |
| Nominal ratings | ||
| Operating voltage | 26.5 … 31.9 V via AS-i bus system | |
| Switching frequency | 0 … 500 Hz | |
| Hysteresis | 1 … 15 typ. 5 % | |
| Reverse polarity protection | reverse polarity protected | |
| No-load current | less than or equal to 25 mA | |
| AC magnetic field | 100 mT | |
| Switching state indicator | two-color LED, yellow | |
| Error indicator | two-color LED, red | |
| Safety-related parameters | ||
| MTTFd | 2140 a | |
| Service life (TM) | 20 a | |
| Diagnostic coverage (DC) | 0 % | |
| Certificates and approvals | ||
| UL approval | cULus Listed, General Purpose | |
| CSA approval | cCSAus Listed, General Purpose | |
| CCC approval | CCC approval/marking not required for products with a rated voltage of 36 V or less | |
| Ambient conditions | ||
| Ambient temperature | -25 … 70 °C (-13 … 158 °F) | |
| Storage temperature | -40 … 85 °C (-40 … 185 °F) | |
| Mechanical specifications | ||
| Connection type | Connector M12 x 1 , 4-pin | |
| Housing material | Stainless steel 1.4305 / AISI 303 | |
| Sensing face | PBT | |
| Housing diameter | 12 mm | |
| Degree of protection | IP67 | |