| Mounting | on Termination Board |
| Mass | approximately 100 g |
| Certificate | KIWA 15 ATEX 0037 X |
| Switching frequency | 5 kHz |
| Labeling | space for labeling at the front |
| Dimensions | 12.5 x 128 x 106 mm (0.5 x 5.1 x 4.2 inch) |
| Power consumption | 600 mW |
| Signal type | Digital Input |
| Output type | open collector transistor (internal fault bus) |
| Line fault detection | breakage I 0.1 mA, short-circuit I 6.5 mA |
| Output/Output | basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 Veff |
| Rated current | 25 mA |
| Rated values | acc. to EN 60947-5-6 (NAMUR), see system description for electrical data |
| Ripple | 10 % |
| Coding | pin 1 and 2 trimmed For further information see system description. |
| Connection | SL2: 5a(+), 5b(-) |
| Control elements | DIP-switch |
| Rated voltage | 19 … 30 V DC |
| Connection side | field side |
| Rated voltage | 19 … 30 V DC bus powered via Termination Board |
| Output/power supply | basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 Veff |
| EU-Type Examination Certificate | BVS 11 ATEX E 026 |
| Safety Integrity Level (SIL) | SIL 2 |
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Open circuit voltage/short-circuit current | approx. 10 V DC / approx. 8 mA |
| Response time | 200 micro/s |
| Degree of protection | IP20 |
| Electromagnetic compatibility | NE 21:2012, EN 61326-3-2:2008 |
| Output I, II | signal or error message, passive transistor output (resistive) 0-signal: 15 kΩ ± 5 % 1-signal: 5 kΩ ± 5 % fault: > 100 kΩ |
| Connection side | control side |
| Degree of protection | IEC 60529:2001 |
| Pulse/Pause ratio | min. 100 µs / min. 100 µs |
| Connection | SL1: 1a(-), 1b(-); 2a(+), 2b(+) |
| Switching point/switching hysteresis | 1.2 … 2.1 mA / approx. 0.2 mA |
| Protection against electrical shock | IEC 61010-1 |
| Ambient temperature | -20 … 60 °C (-4 … 140 °F) |
| Display elements | LEDs |
| Configuration | via DIP switches |
| Power dissipation | 500 mW |
| Connection | SL1: 6b |
| Connection | SL1: 8a(+), 7a(-); 10a(+), 9a(-) |
The switching frequency is 5 kHz. There is space for labeling at the front of the device. The dimensions are 12.5 x 128 x 106 mm (0.5 x 5.1 x 4.2 inch). The power consumption is 600 mW.
The signal type is Digital Input. The output type is an open collector transistor (internal fault bus). Line fault detection for breakage is 0.1 mA, and for short-circuit is 6.5 mA. The output/output has basic insulation according to IEC/EN 61010-1, with a rated insulation voltage of 60 Veff. The rated current is 25 mA. Rated values are according to EN 60947-5-6 (NAMUR); refer to the system description for electrical data. Ripple is 10%. Coding is via trimmed pins 1 and 2. For further information, consult the system description.
The connection is via SL2: 5a(+) and 5b(-). Control elements include DIP-switches. The rated voltage is 19 … 30 V DC for both the connection side (field side) and the output/power supply. The output/power supply has basic insulation according to IEC/EN 61010-1, with a rated insulation voltage of 60 Veff. The EU-Type Examination Certificate is BVS 11 ATEX E 026. The Safety Integrity Level (SIL) is SIL 2. Supplementary information includes observing applicable certificates, declarations of conformity, instruction manuals, and manuals. For details, visit www.pepperl-fuchs.com. The open circuit voltage/short-circuit current is approx. 10 V DC / approx. 8 mA. The response time is 200 microseconds. The degree of protection is IP20. Electromagnetic compatibility is in accordance with NE 21:2012 and EN 61326-3-2:2008.
Output I, II are signal or error messages, passive transistor outputs (resistive). The 0-signal is 15 kΩ ± 5%, the 1-signal is 5 kΩ ± 5%, and a fault is indicated by > 100 kΩ. Connection side (control side) has a degree of protection according to IEC 60529:2001. Pulse/Pause ratio is min. 100 µs / min. 100 µs. Connection is via SL1: 1a(-), 1b(-); 2a(+), 2b(+). Switching point/switching hysteresis is 1.2 … 2.1 mA / approx. 0.2 mA. Protection against electrical shock is according to IEC 61010-1. Ambient temperature range is -20 … 60 °C (-4 … 140 °F). Display elements include LEDs. Configuration is done via DIP switches. Power dissipation is 500 mW. Additional connections are SL1: 6b and SL1: 8a(+), 7a(-); 10a(+), 9a(-).