| Climatic testing | DIN EN 60068-2-3, no moisture condensation |
| Operating voltage | 4.5 … 30 V DC |
| Monoflop time | 20 ± 10 µs |
| Switch-on delay | |
| Connector | type 9416 (M23), 12-pin, type 9416L (M23), 12-pin |
| L₁₀h | 1.9 E+11 at 6000 rpm and 20/40 N axial/radial shaft load |
| Mass | approx. 460 g (combination 1) approx. 800 g (combination 2) |
| Input current | |
| Vibration resistance | DIN EN 60068-2-6, 20 g, 10 … 2000 Hz |
| Detection type | photoelectric sampling |
| Switch-on delay | |
| Input type | zero-set (PRESET 1) |
| MTTFd | 150 a |
| Voltage drop | U — 2.5 V |
| UL approval | cULus Listed, General Purpose, Class 2 Power Source |
| Code course (counting direction) | cw descending (clockwise rotation, code course descending) |
| Shock resistance | DIN EN 60068-2-27, 100 g, 6 ms |
| Degree of protection | DIN EN 60529, IP65 (without shaft seal) ; DIN EN 60529, IP66/IP67 (with shaft seal) |
| Input current | |
| Storage temperature | -40 … 85 °C (-40 … 185 °F) |
| Cable | andempty;7 mm, 6 x 2 x 0.14 mm², 1 m |
| No-load supply current | max. 180 mA |
| Interface type | SSI |
| Time delay before availability | |
| Device type | Multiturn absolute encoder |
| Rotational speed | max. 12000 min⁻¹ |
| Diagnostic Coverage (DC) | 0 % |
| Starting torque | |
| Emitted interference | DIN EN 61000-6-4 |
| Input type | Selection of counting direction (cw/ccw) |
| Moment of inertia | 50 gcm² |
| Linearity | ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, ± 0.5 LSB at 12 Bit |
| Output code | Gray code, binary code |
| Operating temperature | -40 … 85 °C (-40 … 185 °F) |
| Noise immunity | DIN EN 61000-6-2 |
| Transfer rate | 0.1 … 2 MBit/s |
| Mission Time (T) | 20 a |
| Standard conformity | RS 422 |
The mass of the device is approximately 460 g for combination 1 and 800 g for combination 2. It has a vibration resistance of DIN EN 60068-2-6, 20 g, 10 … 2000 Hz and a shock resistance of DIN EN 60068-2-27, 100 g, 6 ms. The detection type is photoelectric sampling. The input type for zero-set (PRESET 1) and selection of counting direction (cw/ccw) are supported. The MTTFd is 150 years.
The voltage drop is U — 2.5 V. It has UL approval as cULus Listed, General Purpose, Class 2 Power Source. The counting direction is cw descending. The degree of protection is DIN EN 60529, IP65 (without shaft seal) and DIN EN 60529, IP66/IP67 (with shaft seal). The storage and operating temperatures range from -40 to 85 °C (-40 to 185 °F).
A cable of length 1 m, with a diameter of ) is 20 years. Standard conformity is RS 422. The moment of inertia is 50 gcm². Linearity is ± 2 LSB at 16 Bit, ± 1 LSB at 13 Bit, and ± 0.5 LSB at 12 Bit. Output codes include Gray code and binary code. Emitted interference complies with DIN EN 61000-6-4, and noise immunity complies with DIN EN 61000-6-2.