MTTFd880 a
| Mission Time (TM) | 20 a |
| Switching type | Light-on/dark-on changeover switch |
| Black/White difference (6 %/90 %) | < 20 % at 2000 mm sensor range |
| Control elements | Sensing range adjuster, light-on/dark-on changeover switch, changeover switch for mode of operation Background suppression / Background evaluation ; Adjuster for edge monitoring left/right |
| Operating voltage | 17 … 30 V DC , 18 … 28 V AC |
| Ambient temperature | -20 … 60 В°C (-4 … 140 В°F) |
| Connection | screw terminals |
| Detection range max. | 0 … 2500 mm with background evaluation, 500 … 2500 mm with background suppression |
| Diameter of the light spot | 75 x 75 mm by sensing range 2000 mm |
| Function indicator | LED red |
| Diagnostic Coverage (DC) | 60 % |
| Light source | IRED |
| Detection range min. | 0 … 1500 mm by background evaluation, 500 … 1500 mm by background suppression |