OD3 Attenuator, 818-SL-L Detector |
Additional Features:
- Power and precision typical of a benchtop meter
- Includes both DC and AC peak-to-peak measurement modes
- Power sensitivity from 100 pW to 2 W (-70 to +33 dBm)
- Wavelength and range settings
- Linear, dB, dBm and linear ratio readouts
- Background subtraction and digital averaging
- Wavelength selection in 1 nm steps
- Audible tone for no-look tuning
- Rechargeable batteries for full portability
- Most recent operating parameters are saved when unit is turned off
Specifications
- Display Type: 4-digit LCD w/ backlight
- Sampling Rate (Hz): 2.5
- Gain Ranges: 6 decades, DC, 4 decades, AC Pk-Pk
- Full Scale Readings, Low-Power Detector: 100 nA–5 mA
- DC Accuracy, 100 nA range, full scale: ± (0.5% + 50 pA)
- DC Accuracy, 1 µA to 5 mA range, full scale: ± (0.25% + offset)
- Peak-to-Peak Accuracy, 50 Hz to 1 kHz: Squarewave ±5%, Sinewave ±1%
- Peak-to-Peak Accuracy, 1 kHz to 2 kHz: Squarewave ±1%, Sinewave ±2%
- Peak-to-Peak Accuracy, 2 kHz to 5 kHz: Squarewave ±2%, Sinewave ±5%
- Analog Output Accuracy, 100 nA range: ± (2.5% + 15 mV)
- Analog Output Accuracy, 1 µA to 5 mA range: ± (2% + 10 mV)
- Analog Output: BNC, 0–1 V into 1 MΩ
- Temperature Coefficient: 0.1 x Accuracy/°C
- Battery Life: 18 hours (backlight on)
- Battery: Ni-Cd rechargeable
- Wall Power: AC adaptor/Charger
- Dimensions (H x W x D) (in.) (mm): 7.2 (183) x 3.0 (76) x 1.5 (38)
- Operating Temperature: 0°C to 50°C, <,80% RH
- Storage Temperature Range: -25°C to 60°C, <,90% RH
The Newport Model 840-C hand-held optical power meter is fully compatible with all of Newport»s 818 Series Low-Power Si, Ge and InGaAs detectors. Detectors connect to the power meter through an in-line calibration module that is dedicated to each detector. These detachable modules provide the Model 840-C with calibration and operating information specific to the assigned detector. Various detector accessories allow for free-space, as well as for fiber coupled power measurements. DC and AC peak-to-peak power measurements can be displayed in units of W and dBm on the instrument»s 4-digit, backlit LCD.
The 840-C is compatible with Newport»s Ge, Si and InGaAs detectors, allowing both free-space and fiber pigtailed measurements in the 200–1800 nm range. When using 818 Series detectors with the 840-C, a calibration module needs to be attached to the detector (818-xx/CM), assuring the correct reading at any pre-selected wavelength. Newport»s new 918D and 918L Series detectors can also be used with the 840-C, in combination with the 818P-DIN adapter.
Технические характеристики
Manufacturer | Newport |
---|---|
Condition | Used |