NuAire 6 Класс II Тип B1 BSC 120 В 60 Гц. Применение аптеки

Доставка импортных компонентов Nuaire по России от 3х недель транспортными компаниями СДЭК, Деловые Линии, Major Express.
Оплата физическими и юридическими лицами безналичным расчетом.
Цена может измениться после запроса у поставщика!

Product Description Never Been Used (some slight cosmetic damages due to shipping) 1-Year Factory Warranty Exhaust Interlock System Backwall Channel Paper Catch External Fluorescent Lighting Heavy Duty Ergonomic PVC Armrest Removable Work Tray 15 Amp Type B Outlet (3 amp max) (Qty 1) (Left Front Faring) (115V) Right Middle Service Coupling Right Bottom Service Valve Spill Trough with Drain Valve 100% Front Service Access Ergonomics A Comfortable Work Environment Make your more comfortable and productive with the forearm support and ample knee and thigh clearance of this LabGard&reg: cabinet. The built-in height adjustment lets you set the workstation at the proper level for fatigue-free use. The cool white lighting reduces glare and eye strain, and the extensive work and viewing area make repetitive movements easier to prevent cramped necks, arms, and shoulders. Easy Operation at a Glance Operate system functions from the color touchscreen of the TouchLink2 ECS. This electronic control system manages lights, the blower, and interior outlets, and it can monitor airflow limits, window position and filter status. Use the timer to set purge cycles and time outlets, UV lights, nighttime setback and weekend shutdown. The Building Automation System lets you query and monitors operating information remotely. Technology HEPEX Zero-leak Airflow System Depend on the HEPEX zero-leak airflow system to eliminate potential leaks by surrounding positive-pressure chambers and ducts with negative pressure. The fabrics in the HEPEX system are durable, flameproof and antibacterial. They also resist water, gases, fluid, dust, chemicals, oils and greases. True Laminar Airflow Reduce the chance of cross-contamination with the true laminar airflow. This system keeps unidirectional airflow moving along parallel lines at a constant velocity to reduce turbulence. Use the IntelliFlow systems dual thermistor airflow sensors to control real-time down flow and exhaust flow. Dynamic Air Barrier and Exhaust Interlock The dynamic air barrier ensures strong inflow air velocity over the aerodynamic airfoil. The exhaust interlock system prevents the internal supply blower from operating when the exhaust flow is insufficient to provide enough air-barrier inflow velocity. TouchLink 2.0 Electronic Control System Control the essential functions of the CellGuard cabinet with the TouchLink2 electronic control system. The system provides touchscreen control of lights, motors, interior outlets and more, and it can monitor airflow limits and window position. Use the timer to control many time-sensitive functions and the Building Automation System to query and monitor operating information remotely. Construction Nothing Else is Built like a NuAire Monolithic Construction The uni-body design of this LabGard&reg: cabinet provides a single-shell, fully welded cabinet made of high-grade stainless steel to eliminate leaks creating a true pressure tight design. Filter Integrity Check Model NU-427 features larger 99.99% @ 0.3 &mu, efficiency HEPA filters that are tested using IEST Recommended Practices as prescribed by Biosafety Cabinetry standard NSF/ANSI 49. Exhaust and Supply HEPA filters feature more filter media equating to longer filter life and lower operating costs. HEPA filters are tested twice during the manufacturing process. Once before the filter is installed and again fitted in the Biosafety cabinet before it ships. This integrity check process ensures you receive the safest Biosafety cabinet out of the box with zero headaches. We believe in our process so much we included our filters in our warranty. Save Energy Nighttime Setback Use the NiteCare night setback mode when this LabGard&reg: cabinet is idle to save energy while ensuring a sterile work environment. High-Efficiency Motor Ultra high-efficiency motor technology increases filter life to 10 years or more while lowering energy costs. It also reduces motor noise and vibration for a quieter work environment. Technical Specifications Catalog Number Catalog Number NU-427-400Nominal 4 foot (1.2m) NU-427-600 Nominal 6 foot (1.8m) Performance Specifications Personal Protection Product Protection NSF/ANSI 49 NSF/ANSI 49 NSF Std. No. 49 Class Class II, Type B1 Class II, Type B1 Style of Cabinet Bench Top/Console w/Base Stand/Storage Cabinet Bench Top/Console w/Base Stand/Storage Cabinet Cabinet Construction All Welded Stainless Steel 16GA,Type 304 Pressure Tight Design All Welded Stainless Steel 16GA,Type 304 Pressure Tight Design Diffuser for Air Supply (Metal) Non-Flammable Non-Flammable HEPA Filter Seal Type:Supply Filter-99.99% Eff. on 0.3 MicronsExhaust Filter-99.99% Eff. on 0.3 Microns HEPEX SealNeoprene, Spring loaded HEPEX SealNeoprene, Spring loaded Fumigation per NIH/NSF Procedure Yes Yes Standard Services:Service Coupling (3/8 inch NPT)Gas Valve/Service Coupling (3/8inch NPT)Duplex Outlet OneOne, Right SidewallOne, Left Front Faring OneOne, Right SidewallOne, Left Front Faring Optional Services: Gas Cocks 3/8 NPTRemote Controlled Valves** Ultraviolet LightStandard/Cup Sinks Up to 3 ea. Sidewall Up to 3 ea. Sidewall One, BackwallLeft or Right Work Surface Up to 3 ea. Sidewall Up to 3 ea. Sidewall One, BackwallLeft or Right Work Surface Cabinet Size Inches (mm): Height (Fully Assembled)Height (Minimum for Transport) WidthDepth (with Control Center) 61 (1549)61 (1549)53 5/8 (1362)32 7/8 (835) 61 (1549)61 (1549)77 5/8 (1972)32 7/8 (835) Work Access Opening Inches (mm): Standard Opening HeightStandard Inflow Velocity 8 (203)105 FPM (.53 m/s) 8 (203)105 FPM (.53 m/s) Work Zone Inches (mm): HeightWidth Depth 25 1/2 (648)46 3/8 (1178)23 1/2 (597) 25 1/2 (648)70 3/8 (1788)23 1/2 (597) Viewing Window Inches (mm): Standard is Tempered Sliding GlassHinged Tempered Glass (optional) 1.0 (25mm) Closed18 1/2 (470) Open8 (203) Access Opening 1.0 (25mm) Closed18 1/2 (470) Open8 (203) Access Opening Certification Exhaust Value CFM/CMHConcurrent Balance Value CFM/CMH + 270/460282/479 410/697474/805 Plant Duct Static Pressure Eng/Metric 0.7 w.g./18mm w.g. 0.9 w.g./23mm w.g. Heat Rejected, BTU, Per Hour 543 774 Electrical: 115V/(230V) Volts, AC (Hz)++Amps: Blower/Lights Amps: DuplexAmps: Total12 ft. Power Cord (one) U.L./U.L.-C (115V) 115, 602.631014 GA 3 Wire, 15A U.L./U.L.-C (115V) 115, 604.531214 GA-3 Wire, 15A Crated Shipping Weight:Net Weight 600 lbs. / 272 kg.550 lbs. / 249 kg. 790 lbs. / 358 kg.740 lbs. / 336 kg. This LabGard&reg: Class II, Type B1 Biosafety cabinet is suitable for work with minute quantities of volatile chemicals and trace amounts of radionuclides in the direct-exhausted portion of the cabinet or if the chemicals or radionuclides will not interfere with the work when recirculated in the down-flow air.

Технические характеристики

Technical Specifications

Catalog NumberCatalogNumber
NU-427-400Nominal 4 foot (1.2m)

NU-427-600

Nominal 6 foot (1.8m)

Performance Specifications Personal Protection Product ProtectionNSF/ANSI 49NSF/ANSI 49
NSF Std. No. 49 ClassClass II, Type B1Class II, Type B1
Style of CabinetBench Top/Console w/Base Stand/Storage CabinetBench Top/Console w/Base Stand/Storage Cabinet
Cabinet ConstructionAll Welded Stainless Steel 16GA,Type 304 Pressure Tight DesignAll Welded Stainless Steel 16GA,Type 304 Pressure Tight Design
Diffuser for Air Supply (Metal)Non-FlammableNon-Flammable
HEPA Filter Seal Type:Supply Filter-99.99% Eff. on 0.3 MicronsExhaust Filter-99.99% Eff. on 0.3 MicronsHEPEX SealNeoprene, Spring loadedHEPEX SealNeoprene, Spring loaded
Fumigation per NIH/NSF ProcedureYesYes
Standard Services:Service Coupling (3/8 inch NPT)Gas Valve/Service Coupling (3/8inch NPT)Duplex OutletOneOne, Right SidewallOne, Left Front FaringOneOne, Right SidewallOne, Left Front Faring
Optional Services: Gas Cocks 3/8′ NPTRemote Controlled Valves** Ultraviolet LightStandard/Cup SinksUp to 3 ea. Sidewall Up to 3 ea. Sidewall One, BackwallLeft or Right Work SurfaceUp to 3 ea. Sidewall Up to 3 ea. Sidewall One, BackwallLeft or Right Work Surface
Cabinet Size Inches (mm): Height (Fully Assembled)Height (Minimum for Transport) WidthDepth (with Control Center)61 (1549)61 (1549)53 5/8 (1362)32 7/8 (835)61 (1549)61 (1549)77 5/8 (1972)32 7/8 (835)
Work Access Opening Inches (mm): Standard Opening HeightStandard Inflow Velocity8 (203)105 FPM (.53 m/s)8 (203)105 FPM (.53 m/s)
Work Zone Inches (mm): HeightWidth Depth25 1/2 (648)46 3/8 (1178)23 1/2 (597)25 1/2 (648)70 3/8 (1788)23 1/2 (597)
Viewing Window Inches (mm): Standard is Tempered Sliding GlassHinged Tempered Glass (optional)1.0” (25mm) Closed18 1/2 (470) Open8 (203) Access Opening1.0” (25mm) Closed18 1/2 (470) Open8 (203) Access Opening
Certification Exhaust Value CFM/CMHConcurrent Balance Value CFM/CMH +270/460282/479410/697474/805
Plant Duct Static Pressure Eng/Metric0.7” w.g./18mm w.g.0.9” w.g./23mm w.g.
Heat Rejected, BTU, Per Hour543774
Electrical: 115V/(230V) Volts, AC (Hz)++Amps: Blower/Lights Amps: DuplexAmps: Total12 ft. Power Cord (one)U.L./U.L.-C (115V) 115, 602.631014 GA — 3 Wire, 15AU.L./U.L.-C (115V) 115, 604.531214 GA-3 Wire, 15A
Crated Shipping Weight:Net Weight600 lbs. / 272 kg.550 lbs. / 249 kg.790 lbs. / 358 kg.740 lbs. / 336 kg.

This LabGard&reg: Class II, Type B1 Biosafety cabinet is suitable for work with minute quantities of volatile chemicals and trace amounts of radionuclides in the direct-exhausted portion of the cabinet or if the chemicals or radionuclides will not interfere with the work when recirculated in the down-flow air.