Electromagnetic safety lock control with 936 N force and 100% stainless steel No power or under-voltage locking on machine casings Machine protection closing control for harsh environments Antimicrobial handle available Level of performance with AWAX controller: up to PL = e • Safety category: up to 4 with AWAX controller or PLC SIL 3 • Time before dangerous failure: MTTFd = 100 years • Maximum detection activation distance: 2 mm • Holding force: up to 936 N (ref. version + OX-R) or up to 820 N (ref. version + OX-E) • Safety contacts/diagnostics: 2 x NO 250mA max/24V redundant and • 1 x PNP 250mA • Detection encoding: mono-code inviolable • Reset: automatic or controlled (ref. + OP) • Housing mount: 4 tamper-proof M6 screws (optional ref: BH6) • Handle attachment: 2 M8 screws • Mounting position: 1 • Casing material: 316L stainless steel mirror polished (OX version) • Suction cup material: Magnetic INOX (ref. + OX) • Electrical Connection: 50cm PUR cord with M12 connector • Water resistance: IP 69K • Temperature: -25°C to +50°C (thermal protection for suction cups in case of overheating due to a persistent command) • Marking: laser engraving with mechanically punched serial number for • permanent traceability
Технические характеристики
CharacteristicsOptionsmulti-point, electronic