Поставка оптоэлектронных компонентов ведущих мировых производителей

МСД Agilent 5975

Доставка импортных компонентов Agilent по России от 3х недель транспортными компаниями СДЭК, Деловые Линии, Major Express.
Оплата физическими и юридическими лицами безналичным расчетом.
Цена может измениться после запроса у поставщика!
Артикул: 8012-30-0022 TME арт.: 8012-30-0022

Product Description #gap-623835923 { padding-top: 30px, } Proven performance, superior productivityand maximum confidence in your results. Welcome to the next generation of the industry-proven Agilent 5975C Series GC/MSDthe most popular GC/MS of all time. The Agilent 5975C inert GC/MSD combines innovative design features to boost your labs productivity, and advanced analytical capabilities that help you achieve better results faster. Perfectly complemented by the new 7890A GC, the platform delivers all the elements for perfect chemistrysuperior performance, unmatched reliability, greater productivity and enhanced ease of use. #gap-2144602974 { padding-top: 30px, } Advanced Analysis Capabilities The modular mass analyzer incorporates a proprietary quartz quadrupole, a solid inert ion source and industry-leading detector. This powerful combination provides better MS resolution and the lowest mass deviation available, it also assures superior sensitivity and spectral integrityfor the highest confidence in your results. New Trace Ion Detection technology provides even more capabilities at trace level. #col-1532695110 > .col-inner { padding: 0px 0px 0px 0px, } Higher Throughput Comprehensive automation features and faster separation and detection cycle times enable you to process more samples, with more confidence. Advanced analysis routines let you get more information from every run, and automated spectral deconvolution, identification and quantification software simplifies post-run analysis. Maximum Uptime Thoughtful, real-world engineering features allow faster, easier routine maintenance, and new self-diagnostic and preventive maintenance software makes it easier than ever to keep your lab up and running at peak performanceall the time. Engineering thats all about performance and productivity. At Agilent, building the worlds most trusted GC/MS solutions is an ongoing challenge and a process of continual improvement. With each new generation of instruments, we never lose sight of our goalto help your lab get better results with higher confidence, and process more samples in the shortest possible time. The gold standard in quadrupole design and performance The quadrupole used in the Agilent 5975C Series GC/MSD incorporates a combination of patented, proprietary Agilent technologies to deliver superior performance and significantly enhanced reliability. The true hyperbolic quartz structure offers extremely low thermal expansion, and exhibits excellent dimensional stability. The unique design results in lower field errors versus round rod quadrupoles, as well as excellent resolution and mass axis stability, regardless of laboratory temperature fluctuations. The submicron-layered gold hyperbolic electrode surfaces give maximum transmission while maintaining resolution across the full mass range, up to 1050 u. Bakeout to 200C enables more robust determinations, as well as outstanding high mass stability and minimal maintenance. An available high mass checkout kit provides added confidence that high mass is accurately reported. Solid inert ion source up to 350? C boosts your system performance Agilents proprietary inert source is now programmable up to 350?C to provide enhanced response for active compounds and late-elutersincluding pesticides. It delivers exceptional electron impact ionization, and lets you run sample after sample with complete confidence. The source is constructed of a solid inert material, so there is no inert coating that can wear away over time and which can ultimately compromise your data. The inert ion source eliminates surface activity reactions, for more reliable library matches. It also requires less frequent cleaning, improving your labs productivity. The inert ion source eliminates surface activity reactions, for more reliable library matches. It also requires less frequent cleaning, improving your labs productivity. Trace Ion Detection delivers a real performance improvement for complex matrices Revolutionary Trace Ion Detection technology lets you lower your Method Detection Limit (MDL), as well as your limit of quantitation (LOQ). It reduces false negatives and further enhances the performance of the inert ion source at trace levels. The technology also ensures more reproducible baselines, dramatically reducing the number of manual interventions during peak integration. Trace Ion Detection technology gives you a better spectral fidelity, increasing your confidence level in the results when doing library matching. High sensitivity AutoTune makes it easy to optimize system performance Take the trial and error out of optimizing operating conditions by automating the process. The 5975C systems AutoTune feature saves time, boosts performance and improves instrument-toinstrument consistency. Powerful analytical capabilities improve results and productivity. #gap-1191295476 { padding-top: 18px, } Fast electronics enhance performance and enable synchronous SIM/Scan Fast electronics used in the 5975C Series GC/MSD maximizes signal transmission for fast GC/MS in full scan and Selected Ion Monitoring (SIM) modes. It also enables synchronous SIM/Scan functionalitywithout compromising analytical performance. High-Performance Selected Ion Monitoring (SIM) and Full Scan Agilents synchronous SIM/Scan functionality lets you capture SIM data and full scan data in the same acquisition. Because of the ease of setup and availability of spectral libraries, many labs use full scan for most of their data collection. SIM mode, on the other hand, offers a significant improvement in sensitivity over full scan data, however, SIM data cannot be searched against commercially available spectral libraries for match confirmation. Now, with the 5975C systems synchronous SIM/Scan operation, you can get bothin a single run! Even better, you dont have to be a GC/MS expert to do it. Agilents AutoSIM software capability automatically converts full scan data into SIM or SIM/Scan acquisition parameters for use in synchronous SIM/Scan methods. SIM dwell times can be set in 1 msec increments from over 100 msec to as low as 1 msec dwell time. CI as easy as EI Chemical Ionization (CI) has long been considered an advanced GC/MS technique because of complex setups, reagent gas adjustment and ion source tuning. Now the Agilent 5975C inert GC/MSD makes CI as routine and easy as EIwithout sacrificing the spectral information of EI. The dual inlet port configuration allows you to operate your CI system at optimum performance levels without having to constantly reconfigure. Methane is used to optimize the ion source and perform the mass calibration, a separate inlet port is provided for a second reagent gas, including ammonia. An intuitive software user interface and a CI flow control module work together to automatically adjust the CI reagent gas flow for optimum CI performance. #gap-1214337460 { padding-top: 30px, } The Agilent 7890A Gas Chromatograph: The next level of GC performance and productivity. Adding an exciting new chapter to a 40-year history of GC leadership, Agilents new 7890A flagship GC gives you everything you need to take your lab to the next level of GC/MS performance, including advanced chromatographic capabilities, powerful new productivity features and real-time self-monitoring instrument intelligence. Plus, of course, legendary Agilent reliability. Agilent Performance and Reliability 5th-generation electronic pneumatics control (EPC) and digital electronics set a new benchmark for retention time locking (RTL) precision and retention time repeatability, and help make the 7890A Agilents most dependable GC ever. Expanded Chromatographic Capabilities Highly flexible EPC design enables even more sophisticated hydrocarbon analyses. An optional 3rd detector (TCD) can speed up complex gas analyses, and allows more types of analyses to be run on a single GC. Higher Productivity Faster oven cool-down, robust backflush capability, advanced automation features and faster GC/MS oven ramps let you get more done in less time, at the lowest possible cost per sample all easily incorporated into your existing methods. Easier Operation Practical, time-saving design features speed up and simplify routine maintenance. #gap-653594024 { padding-top: 30px, } The Agilent 7890A GC works right into your current 6890 workflow, with no major changes to your methods You can increase your productivity and take advantage of the new capabilities of the 7890A system with no disruption to your labs smooth operation. Right out of the box, operators will be right at home with the familiar controls and user interfaceand because the 7890A system is built upon proven 6890 GC inlets, detectors and GC oven, you can transfer methods to your new 7890A GC with complete confidence. Breakthrough Capillary Flow Technology Agilents innovative Capillary Flow modules enable reliable, leakfree in-oven connections. Available in a number of useful configurations, these inert, low-mass, low-dead-volume devices not only make it easy to make secure connections, they give you the ability to precisely divert your gas flow, where and when you want. This opens the door to highly useful techniques, such as flow splitting, backflushing and Deans Switching, that can improve your analytical results, as well as saving time and resources. Perform SSL inlet maintenance in seconds Convenient new Turn-Top design is built into each split/splitless (SSL) inlet, allowing you to change liners and columns more quickly and easily than ever beforewithout special tools or training. The Agilent 6850 Series II GCsmall, rugged, easy to useIs your lab doing simple, routine applications or at-line analysis? The Agilent 6850 GC, combined with the 5975C VL GC/MSD, is the perfect choice if you need just a single inlet and detector. The small-footprint system offers a surprising number of advanced featuresas well as legendary Agilent reliability. GC/MS software that fits your workflow and your applicationperfectly. The Agilent MSD Productivity ChemStation makes it easy even for non-expert operators to take advantage of all the advanced capabilities of the Agilent 5975C inert GC/MSD system. Youll find everything designed to help you make the most of every run, and every workday. The MSD ChemStation software includes four industryfocused packages: Enhanced Mode, EnviroQuant, DrugQuant and Aromatics in Gasoline. Unique productivity features Control of two GC/MS systems from a single MSD ChemStation via built-in LAN communication saves time, resources and bench space. Automatic tuning ensures more accurate results every time for EI, PCI and NCI modes. Retention Time Locking (RTL) gives you repeatable retention times across systems regardless of operator, detector type and column maintenance. In combination with Agilent or user-created databases, it will let you quickly screen unknown peaks with added confidence. Synchronous SIM/Scan and AutoSIM automatically and easily convert any full scan method to a high sensitivity SIM or SIM/Scan methodenabling you to acquire both SIM and Scan data in a single run. eMethods functionality allows you to efficiently share and distribute methods across multiple laboratories or to save development time by downloading application methods from the Agilent Website. SemiQuant estimates the concentration of uncalibrated compounds that may be of potential importance. Data reprocessing lets you reprocess a previously run sequence while new data are being collected. Enhanced Data analysis and Easy EIC tools expand your systems qualitative analysis capabilities. Enhanced flexibility features Simple, standard reports or easily customizable reports let you best meet your labs needs. A variety of reports may also be easily exported to XLS, HTML or XML formats. Advanced macro programming provides additional capability for customization. Integrated control of PAL autosamplers enables automated, largevolume sample injection. (Available option) Deconvolution Reporting Software (DRS), combined with application-specific Retention Time Locked Libraries, reduces hours of manual data review to only minutes of automated processing. (Available option) Integration with Agilent OL Enterprise Content Manager (ECM) makes it easy to store, retrieve and organize GC/MS methods, data and reports. SemiQuant, Quickly and easily estimate the concentration of non-calibrated compounds Agilents SemiQuant capability works together with Retention Time Locking (RTL) databases to increase confidence in your compound identification and speed up the quantification process. When an unknown peak appears, a library search provides only a possible match with the sample spectrum. Using the appropriate RTL database, you can increase certainty by matching the retention time of your compound with a fixed retention time in addition to spectral data. Should you wish to quantify the compound, SemiQuant helps by estimating the concentration, so that you can inject the appropriate level of the standard. eMethods, Replicate, share and distribute methods With Agilent eMethods, recreating and replicating a new GC/MS method is now a quick and fully automated process. You can bring a new GC/MS online in the shortest possible time, and maximize lab productivity by standardizing on methodswhether your instruments are across the hall, or across the world. Rapid Deconvolution, Identification and Quantification in Complex Matrices. Agilents simple, easy-to-use Deconvolution Reporting Software (DRS) is an optional software feature that saves hours of analysis and review. The best deconvolution software in the industry, the software quickly finds compounds that traditional data analysis packages miss. In fact, it reduces data review time from hours of tedious work to minutes of unattended computer analysis. The DRS software automates the following operations: Quantitation by target compound analysis software Spectral Deconvolution, or cleaning of full scan spectra Library searching of cleaned spectra The revolutionary solution combines three different software packages: Agilents GC/MSD ChemStation The National Institute of Standards and Technology (NIST) Mass Spectral Search Program with the NIST MS Library NISTs Automated Mass Spectral Deconvolution and Identification Software (AMDIS) Three new database libraries: Hazardous Chemical Compounds RTL Database for rapid and accurate identification of chemical agents Pesticide and Endocrine Disruptor RTL Database for rapid and accurate quantitation of these agents in large numbers of samples Indoor Air Toxics RTL Library for identification and quantitation of toxics in the workplace Accessories and options make your 5975C even more versatile and productive. Automatic Liquid Samplersperfect productivity partners for your 5975C Series GC/MSD Add an Agilent 7683 Series Automatic Liquid Sampler. Offering the fastest injection times of any GC autosampler, greater solvent capacity, multiple sampling options, dual simultaneous injection, certified autosampler vialsand morethe 7683 ALS is ready to go to work. Boost your labs output with automated sample preparation Choose the versatile CombiPAL sample injector for liquid injection, headspace and solid-phase microextraction (SPME). The economical GC PAL platform can be configured for liquid injection only, but offers many of the other capabilities of the CombiPAL including large volume injection (LVI), multiple vial and syringe sizes, and extended sample vial capacity. Agilent G1888A Headspace Sampler adds to your analysis capabilities Automatically introduce volatile compounds from virtually any sample matrix directly into a GC or GC/MS. An inert sample pathway from vial through column to source provides superior chemical performance without analyte degradation or loss. Oil-free pumpclean and virtually maintenance free Agilent is the first mass spectrometer manufacturer to offer this unique pump, which requires virtually no routine maintenance. Theres no oil, and no danger of oil contamination or leaking. Designed for supportability and maintenance Agilent GC/MSD systems have always been designed for easy serviceability and maintenanceand the Agilent 5975C Series GC/MSD takes this design philosophy to a whole new level. Modular analyzer assembly offers complete access to the filament ion source, mass analyzer and electron multiplier for faster routine maintenancein fact, the entire analyzer assembly can be removed in less than two minutes, without tools! A modular, self-contained electronics module minimizes problems with cables and wiring harnesses. Front glass window provides simple source identification, as well as a complete view of critical connectionsso you can see for sure the column is connected properly. High-reliability vacuum system assures maximum long-term performance, available oil-free pumping system virtually eliminates pump maintenance and reduces noise, and can be used with corrosive gases such as ammonia. Off-axis high-energy dynode (HED) detector delivers long life and superior sensitivity. New Electron Multiplier Saver feature further extends system service duty cycle. Optional ion gauge helps to troubleshoot and isolate leaks as quickly as possible. QuickSwap Capillary Flow device saves time and money with every column change and system maintenance Tired of waiting around for a mass spec to vent before you can change a column out or perform routine inlet maintenance? Using a QuickSwap Capillary Flow device, you can safely disconnect the column without venting, and without losing vacuumin about 30 seconds! The QuickSwap device can also be used for column backflushing, reducing MSD contamination by high-boiling sample components, shortening analysis time and increasing the lifetime of your ion source. High performance Agilent J&W columns and supplies for the Agilent 5975C Series GC/MSD. To help you achieve better results faster, Agilent is continuously improving the cleanliness, convenience and reliability of columns and supplies for Agilent GC/MSD systems. From market-leading J&W columnswith rigorous quality control and QC testing that ensure reproducibility, efficiency and inertnessto GC flow path supplies designed, manufactured and packaged to maintain the integrity of your sample, Agilent columns, supplies and accessories will improve your labs performance, productivity and confidence. Performance Choose Agilent J&W columns and supplies for a leak-free, inert flow path to ensure lowest bleed and best signal-to-noise performance in Agilent GC/MSD systems. From among the full suite of Agilent low-bleed J&W columns, the inert HP-5MSi column was selected to ship with the new 5975C. Specially tested to ensure maximum area response performance of strong acid and base compounds, this column is also compatible with Agilent Pesticide Libraries for MS. Tight inlet seals are needed to keep MS system performance at its peak. Agilent liners pre-cleaned and conditioned liner O-rings matched with our new, proprietary, injection-molded gold-plated sealprevent the tiniest leaks that cause column bleed, and signal deterioration. Productivity Agilent supplies help keep routine maintenance routine. Our capillary column ferrules, O-rings and septa are packaged to not only remain clean and ready for use, but to conveniently dispense one at a time as needed for fast inlet maintenance. An exclusive non-stick plasma coating on our premium inlet septa and pre-cleaned O-rings makes maintenance quicker and easier no unscheduled inlet maintenance due to residue on the inlet surface, and shorter bakeout times after preventive maintenance, so you can start running samples sooner. Confidence Agilent J&W columns and supplies ensure your Agilent 5975C system delivers as promised. In fact, our GC and GC/MS instrument specifications are determined using industry-leading Agilent J&W columns and Agilent brand chromatography supplies. Eliminate concerns about lost samples or productivity from unexpected sequence interruptions by using Agilent certified autosampler vials, septa and caps, and Gold Standard syringes. Each comes with a Certificate of Conformance to assure you all specifications are met.

Технические характеристики

Technical Specifications

Mass Selective Detector

Mode (standard) EI
Modes (optional) PCI, NCI, EI with CI source
Ion source typeNoncoated inert EI source for turbomolecular pump systems

(optional for diffusion pump system)

Stainless steel EI source for diffusion pump system

Mass filterMonolithic hyperbolic quadrupole
Maximum mass1050 u
DetectorTriple-Axis HED-EM with extended life EM
Scan rate (electronic) Up to 12,500 u/s
Pumping system 65 L/s diffusion pump, 70 L/s or 262 L/s turbomolecular pump with 2.5m³/h mechanical pump

Gas Chromatograph (6850, 6890N, or 7890A GC)

For more specifications on GCs refer to the GC Data Sheet

InjectorSplit/ splitless (standard), others available
AutosamplerG2880A, 7683, CombiPAL, or 1888A (and more…)
Oven temperatureAmbient +4 °C — 450 °C(6890/ 7890A) or +5 °C -350 °C (6850)
Oven ramps/plateaus6850 and 6890: 6/7, 7890A: 20/21. Negative ramps are allowed.
Electronicpneumatic

control(EPC)

Auto pressure regulation for split/splitless, septum purge
Carrier gas control modesConstant pressure and flow modes, pressure and flow programmable
Pneumatic splitter Capillary Flow Technology devices for effluent splitting backflushing, and column switching

Data System

eMethodsTransfer methods between 5975 and 5973 Series MSDs
Simultaneous MS and GC Six signals for the 7890A GC systems and four signals for the 6890A Series GC systems (up to two MS) detector data acquisitions
SIM/Scan Autmated SIM setup and high performance synchronous SIM/scan operation
Application autotunes One-click autotune for BFB, DFTPP
Spectral libraries (optional) NIST, Wiley, Pfleger-Mauer Drug, Stan pesticide
Spectral DRS and RTl

databases (optional)

Pesticides and endcrine disrupters, volatiles, PCBs, toxicology, FAMEs, flavors, organotin compounds, hazardous chemicals, indoor air toxics, Japan Positive List, forensic toxicology and environment semivolatiles
21CFR11 Compliance Optional software available

Installation Checkout Specifications

EI scan sensitivity1-uL injection of a 1-pg/uL OFN standard scanning from

50 to 300 u will give a nominal m/z 272 ion

With Helium: S/N 400:1 for turbo systems, 200.1 for the diffusion system

With Hydrogen: S/N 100.1 for turbo systems and 50:1 for the diffusion system

PCI scan sensitivity1-uL injection of a 100-pg/uL BZP standard scanning

from 80 to 230 u will give 125:1 S/N with Methane and

500:1 with Ammonia at nominal m/z 183 ion

NCI scan sensitivity2-uL injection of a 100-fg/uL OFN standard scanning

from 50 to 300 u will give 600:1 S/N with Methane and

300:1 with Ammonia at nominal m/z 272 ion

Physical Requirements

(with Agilent 6890 and 7890A GCs)

Dimensions (GC/MSD)88 cm (w) x 56 cm (d) x 50 cm (h)

Additional space should be added for the data system

and printer.

Weight (GC/MSD)81 or 96 kg (depending on configuration)