Additional Features:
- DC Output Voltage: 50V to 6000V with 1V resolution
- Maximum current: 10mA
- Eight HV Scan Channels for multi-point testing
- Resistance Measurements from 0.1MΩ to 50GΩ, Voltage: 50 to 1000 VDC
- Programmable Ramp, Test & Fall Times
- Programmable High & Low Limits
- Open/Short Circuit Check
- Ground Continuity Check with 1ohm Limit
- Arc Detection with Programmable Limit
- Quick Discharge of DUT in IR and DC Hipot
- Storage of 99 Tests Setups with Multiple Steps per Measurement
- Front Panel Lockout
- Standard Remote I/O & RS232 Interfaces
- IEEE-488 or Printer Interfaces Optional
- CE Certified
AC HiPot Applications:
- Production Testing of Appliances, Instruments and Information Technology Equipment in Accordance with UL,IEC,TÜV and Other Standards such as EN60335, EN60950, EN61010, CSA C22.2 No. 1010.1, UL3111 and UL1950
- Transformer electrical safety testing
- Generator/motor safety testing
- Non-electronic safety testing
- Appliance electrical safety testing
- Medical electrical safety testing
The Chroma Guardian 1030S AC/DC/IR/SC HiPot Tester has all of the features of the Guardian 1030 plus eight HV Scan Channels for multi-point testing. In both the DC HiPot and IR tests the device under test is discharged back through the HV transformer. This technique results in a rapid and safe discharge.
The Guardian 1030S has a ground continuity check feature to determine that the resistance, between the ground blade of the power cord and any exposed metal on the product, is less than 1 ohm.
Технические характеристики
| Manufacturer | Chroma |
|---|---|
| Condition | New |