ГХ Agilent серии 6890 с одним детектором

Доставка импортных компонентов Agilent по России от 3х недель транспортными компаниями СДЭК, Деловые Линии, Major Express.
Оплата физическими и юридическими лицами безналичным расчетом.
Цена может измениться после запроса у поставщика!
Артикул: 2012-30-1011 TME арт.: 2012-30-1011

Product Description Configurable with Agilent 6890 Gas Chromatograph Single Split/Splitless or Packed inlet Choice of Single Detector (FID, TCD, or ECD w/upcharge) Electronic Pressure Control (EPC) Manual injection port Computer Data System with preinstalled software New 19 Flat Panel Monitor All cables, keyboard, mouse and complete performance documentation The 6890 the largest selling GC in the world supported by GMI for years to come. GMI recertified GC systems are refurbished to specification and tested by manufacturer trained engineers. Optional Installation and Training available. GMI can provide method development as a professional service. Alternate System Configuration Considerations GMI offers a wide selection of inlets Split/splitless (S/SL) capillary Packed purged injection port (PPIP) Cool on-column (COC) Cool on-column with solvent vapor exit (COC-SVE) Programmable temperature vaporizing (PTV) Volatiles interface (VI) Cooled injection system (CIS) Temperature-programmable pre-column Endlessly configurable Agilent 7683 automatic liquid sampler Agilent G1888 headspace sampler Agilent 7694E headspace sampler Purge and trap Gas and liquid sampling valves Ambient air sampler and preconcentrator Thermal desorber Pyrolyzer No Sample Preparation? Headspace sampling can eliminate sample preparation by introducing volatile components automaticallyfrom virtually any matrixdirectly into the GC. A low-volume, highly inert volatiles interface is optimized for headspace-GC analysis, preventing sample loss or degradation. Agilent headspace instrument control is fully integrated into the software. Variety of Detectors Flame ionization (FID) Thermal conductivity (TCD) Micro-electron capture (micro-ECD) ** Flame photometric, single- or dual wavelength (FPD) Nitrogen-phosphorus (NPD) Pulsed flame photometric (PFPD) Photoionization (PID) Electrolytic conductivity (ELCD) Discharge ionization (DID) Sulfur chemiluminescence (SCD) Nitrogen chemiluminescence (NCD) Mass selective (Agilent 5973N Series MSD) Rentals or Lease? No problem! Wed love to help with your financing or rental needs. Thank you for considering purchasing this re-certified, refurbished-to-specification, Agilent GC from GMI. For over 20 years and over 40,000 satisfied customers, GMI removes 100% of the risk in buying used GC or GCMS chromatography instrumentation to discerning scientists like you.

Технические характеристики

Technical Specifications

6890 Environmental ConditionsAmbient Operating Temperature 15 ˚C to 35 ˚C
Ambient Operating Humidity5-95 %
Average Weight49 kg (108 lb)
Agilent 6890 Column Oven28 x 31 x 16 cm
Operating temperature4˚C above ambient to 450˚C
Maximum ramp time120˚C/min
Available Detectors for the Agilent 6890 GC• Flame ionization detector (FID)
• Thermal conductivity detector (TCD)• Micro-electron capture detector (micro-ECD)• Nitrogen-phosphorus detector (NPD)
• Single- or dual-wavelength flame photometric detectors (FPD)
• Mass selective detector (MSD) — 5972 (economy) & 5973
Sampling Systems Available from GMI• Agilent 6890 Series & 7683 automatic liquid sampler*

• Single or dual injectors, equipped with either an 8-sample turret or a 100-vial sample tray
• Agilent G1888 headspace sampler

• Agilent 7694E headspace sampler

• Purge and trap

• Gas and liquid sampling valves

• Thermal desorber**

Wide selection of inlets• Split/splitless (S/SL) capillary

• Packed purged injection port
(PPIP)

• Cool on-column (COC)

• Cool on-column with solvent
vapor exit (COC-SVE)

• Programmable temperature
vaporizing (PTV)

• Volatiles interface (VI)

• Cooled injection system (CIS)