Поставка оптоэлектронных компонентов ведущих мировых производителей

Гематологическая система Abbott Cell-Dyn Ruby

Доставка импортных компонентов Abbott по России от 3х недель транспортными компаниями СДЭК, Деловые Линии, Major Express.
Оплата физическими и юридическими лицами безналичным расчетом.
Цена может измениться после запроса у поставщика!

Product Description Abbott Cell-Dyn Ruby Hematology System Description Uses MAPSS technology to enumerate and differentiate White Blood Cells and provide the performance needed for patient samples Uses optical laser light scatter analysis to provide both Red Blood Cell and Platelet counts Can process up to 84 CBCs and Differentials per hour MultiAngle Polarized Scatter Separation (MAPSS) laser technology provides enhanced first-pass efficiency, with accurate WBC enumeration and identification using 4 angles of light scatter on up to 10,000 cells per dilution Uses only 4 reagents including reticulocytes Sampling: Open and Closed Reagents: 3 and Retic Load up Capacity: 50 tubes with 10 per rack Maintenance Requirements: Auto-clean (15 min) daily and manual cleaning of syringes, shear valve, dil/sheath filter weekly Specifications Abbott Cell-Dyn Ruby Hematology System Maximum Throughput (Autoloader Mode) CBC + Differential: Up to 84 per hour Sample Volume Open Mode 150 &mu,L, Sample Loader 230 &mu,L Reagents Only 4 reagents including reticulocytes Technology WBC and differential 4 angle optical MAPSS Multiple Scatterplot Analysis Platelets Dual angle optical analysis, no extra reagent, no reflex testing requirement Reticulocytes New Methylene Blue NCCLS method, supravital staining technique Analytical Measurement Ranges WBC 0.02246.8 x 103/&mu,L RBC 0.007.50 x 106/&mu,L HGB 0.025.0 g/dL HCT 8.3-79.8% MCV 58139 fL RDW 10.0-29.8% PLT 0.03000 x 103/&mu,L MPV 4.3-17.2 fL RETC 0.222.9% Data Management Windows-based operating system. Rules-based result annotations. Full on-board QC package. Levey-Jennings plots. Moving Averages. Westgard rules. 10,000 results stored with graphics. Auto calibration online guide. System Control Center A single computer with color touch-screen monitor, keyboard, and mouse Dimensions (HxWxD) Height 19.25 inches (49.9 cm) Width 34 inches (86.4 cm) Depth 30.25 inches (76.8 cm) Weight 232 pounds (105.2 kilograms) Electrical Requirements* VAC 100-240V, 50/60Hz Maximum Power Consumption* 550 watts *Analyzer only. CELL-DYN RUBY GETS YOU THE RESULTS NEEDED, QUICKLY For reliable performance that leads to quality resultsthe first timeCELL-DYN Ruby delivers and outperforms similar tools. With advanced capabilities for the medium-sized laboratory, you can process more complete blood counts in less time. LESS TIME MEANS MORE RESOURCES FOR CRITICAL TASKS The CELL-DYN Ruby reduces the need for microscopic blood smear reviews and repeat testing. Optical technology allows you to allocate resources and ultimately improve your laboratorys efficiency. CONSISTENCY, WHERE AND WHEN IT MATTERS The CELL-DYN Ruby allows you to improve your efficiency by providing rules-based annotations to standardize laboratory processes. This provides consistency in result handling among all your laboratory personnel. INTUITIVE AND SIMPLE SOFTWARE OFFERS CONVENIENCE AND FLEXIBILITY The touch-screen interface is straightforward, easy-to-use, and offers customizable views and handy tool tips to optimize the operators experience. Routine tasks such as reagent and maintenance monitoring are automated, and non-routine tasks, such as calibration, are assisted by the software. Maintenance is simple to perform with the help of on-board videos. ACCURATE, FIRST-PASS OPTICAL PLATELET RESULTS The CELL-DYN Ruby two-angle optical platelet count accurately enumerates and sizes to help ensure first pass reportable results, all while reducing additional testing. EFFICIENT LABORATORY OPERATIONS With only three reagents needed to perform a complete blood count (CBC) with 5-part WBC differential analysis, youll free up operator time to focus on providing patient care. PRECISE AND ACCURATE CELL-DYN Rubys three-dimensional optical red blood cell measurement technology ensures reliable, accurate and precise performance for your hematology workload.

Технические характеристики

Technical SpecificationsAbbott Cell-Dyn Ruby Hematology System

Maximum Throughput (Autoloader Mode)CBC + Differential: Up to 84 per hour
Sample VolumeOpen Mode 150 μL, Sample Loader 230 μL
ReagentsOnly 4 reagents including reticulocytes
TechnologyWBC and differential4 angle optical MAPSS Multiple Scatterplot Analysis
PlateletsDual angle optical analysis, no extra reagent, no reflex testing requirement
ReticulocytesNew Methylene Blue NCCLS method, supravital staining technique
Analytical Measurement RangesWBC0.02–246.8 x 103/μL
RBC0.00–7.50 x 106/μL
HGB0.0–25.0 g/dL
HCT8.3-79.8%
MCV58–139 fL
RDW10.0-29.8%
PLT0.0–3000 x 103/μL
MPV4.3-17.2 fL
RETC0.2–22.9%
Data ManagementWindows®-based operating system. Rules-based result annotations. Full on-board QC package. Levey-Jennings plots. Moving Averages. Westgard rules. 10,000 results stored with graphics. Auto calibration online guide.
System Control CenterA single computer with color touch-screen monitor, keyboard, and mouse
Dimensions (HxWxD)
  • Height — 19.25 inches (49.9 cm)
  • Width — 34 inches (86.4 cm)
  • Depth — 30.25 inches (76.8 cm)
Weight232 pounds (105.2 kilograms)
Electrical Requirements* VAC 100-240V, 50/60Hz
Maximum Power Consumption*550 watts
*Analyzer only.