Festo CPX-E Remote I/O and network interface component.
CPX-E-CEC-M1-EP Datasheet:
| Dimensions (W x L x H) | 75.9 mm x 82.5 mm x 124.3 mm |
| Grid dimension | 18.9 mm |
| Type of mounting | With H-rail |
| Max. number of modules | 10 |
| Product weight | 288 g |
| Mounting position | VerticalHorizontal |
| Ambient temperature | -5 °C … 50 °C |
| Note on ambient temperature | -5 — 60°C for vertical installation |
| Storage temperature | -20 °C … 70 °C |
| Relative air humidity | 95 %Non-condensing |
| Degree of protection | IP20 |
| Corrosion resistance class CRC | 0 — No corrosion stress |
| Vibration resistance | Transport application test with severity level 1 to FN 942017-4 and EN 60068-2-6 |
| Shock resistance | Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27 |
| Protection against direct and indirect contact | PELV |
| LABS (PWIS) conformity | VDMA24364 zone III |
| CE mark (see declaration of conformity) | To EU EMC DirectiveIn accordance with EU RoHS Directive |
| CE marking (see declaration of conformity) | To UK instructions for EMCTo UK RoHS instructions |
| KC mark | KC-EMV |
| Approval | RCM trademarkc UL us listed (OL) |
| Certificate issuing authority | UL E239998 |
| Note on materials | RoHS-compliant |
| Material housing | PA |
| Diagnostics via LED | Force modeModule statusNetwork statusNetwork status, engineering port 1Network status, engineering port 2EtherCAT® network statusNetwork status, port 1Network status, port 2RunPower supply, electronics/sensorsLoad power supplySystem fault |
| Operator controls | DIL switch for RUN/STOPRotary switch for address settingOptional: CDSB operator unit |
| IP address setting | DHCPVia CODESYSOptional: via operator unit CDSB |
| Fieldbus interface | Ethernet |
| Field bus, protocol | ACD (Address Conflict Detection)DLR (Device Level Ring)EtherNet/IPEtherNet/IP QoSEtherNet/IP QuickconnectSNMP |
| Fieldbus interface, function | Bus connection incoming/outgoing |
| Field bus, connection type | 2x socket |
| Field bus, connection system | RJ45 |
| Fieldbus interface, connection pattern | 00995789 |
| Field bus, connection pattern | 8 |
| Field bus interface, electrical isolation | yes |
| Field bus interface, transmission rate | 100 Mbit/s |
| Fieldbus interface 2, type | Ethernet |
| Fieldbus interface 2, protocol | CoEEoEEtherCAT®FoE |
| Fieldbus interface 2, function | Outgoing bus connection |
| Fieldbus interface 2, connection type | Socket |
| Fieldbus interface 2, connection technology | RJ45 |
| Fieldbus interface 2, connection pattern | 00995789 |
| Fieldbus interface 2, number of pins/wires | 8 |
| Fieldbus interface 2, galvanic isolation | yes |
| Fieldbus interface 2, transmission rate | 100 Mbit/s |
| Ethernet interface, connection type | 2x socket |
| Ethernet interface, protocol | EasyIPModbus® TCPOPC UATCP/IP |
| Ethernet interface, function | DiagnosticsSwitch |
| Ethernet interface, connection system | RJ45 |
| Ethernet interface, connection pattern | 00995789 |
| Ethernet interface, number of pins/wires | 8 |
| Ethernet interface, transmission rate | 10 Mbit/s100 Mbit/s |
| Max. address volume, inputs | 64 Byte |
| Fieldbus interface, max. address volume for inputs | 512 Byte |
| Max. address volume, outputs | 64 Byte |
| Fieldbus interface, max. address volume for outputs | 512 Byte |
| System parameters | Diagnostic memoryFail-safe responseSystem start |
| Module parameters | Channel alarms bundlingUndervoltage diagnosticsChannel alarms for undervoltageProcess value representation of analogue modules |
| Configuration support | Control unit CDSBCODESYS V3 |
| Additional functions | CoDeSys V3 with SoftMotion |
| CPU data | 512 MB RAMDual Core 766 MHz |
| storage medium | Micro SD |
| Power supply, function | Electronics and sensors |
| Power supply, connection type | Terminal strip |
| Power supply, note on connection type | > 4 A and UL 2x terminal strip for power supply |
| power supply, connection system | Spring-loaded terminal |
| Power supply, connection pattern | 00995847 |
| Power supply, number of pins/wires | 4 |
| Nominal DC operating voltage, electronics/sensors | 24 V |
| Permissible voltage fluctuations for electronics/sensors | ± 25% |
| Power supply, conductor diameter | 0.2 mmІ … 1.5 mmІ |
| Power supply, note on conductor diameter | 0.2 — 2.5 mmІ for flexible conductors without wire end sleeves |
| Max. power supply | 8 A |
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 150 mA |
| Power failure bridging | 20 ms |
| Reverse polarity protection | 24 V sensor supply against 0 V sensor supply |
| USB-interface | USB 2.0 |
| Programming software | CODESYS provided by Festo |
| Program memory | 100 MB user program |
| Processing time | Approx. 200 µs/1 k instruction |
| Function modules | And othersRead CPX-E module diagnosticsCPX-E diagnostic statusCopy CPX-E diagnostic trace |
| Buffering time real-time clock | 3 Weeks |
| Flag | 120 kB retentive dataCODESYS variable concept |
| Isolation channel — internal bus | yes |
Buy Festo CPX-E-CEC-M1-EP with the best possible price and delivery terms on eltra-trade.com
eltra-trade.com provides top-notch industrial control components. Our online catalog features a diverse selection of products, all available for fast delivery. Benefit from our competitive prices and excellent customer support. Trust us to meet your automation equipment requirements.