Sign up today and we»ll send you a 10% discount code towards your first purchase. Some restrictions apply.
VGDC-J electromagnetic high vacuum damper valve is used to open or close the valve by electromagnetic and spring-return force, applying itself to open or cut off the air current within the Vacuum system. It allows to bear the atmospheric pressure over the valve sealed surface while the downside is full of vacuum as the valve is closed. Under such circumstance can the valve be opened regularly after connecting the electrical control power.
Basic Dimensions
Applicable Scope(Pa)
105~6.7×10-4
Valve Leak Rate(Pa.L/S)
≤6.7×10-4
Applicable Temperature(?)
-25~+40
Coil Temperature Rise(?)
≤65
On and Off Time(S)
3~5
Power Voltage(V/Hz)
220±10%/50
Install Pattern
Vertical
Overall Dimension
Model
Diameter(DN)
ΦW
ΦD
ΦB
H
A
Flange Standard
VGDC-JA-KF16
16
68
30
17.2
186
40
GB4982
VGDC-JA-KF25
25
82
40
26.2
193
50
VGDC-JA-KF40
40
110
55
41.2
270
65
VGDC-A-KF50
50
125
75
52.2
307
70
/
Model
Diameter(DN)
ΦW
ΦB
H
h
bxb
n-b
Flange Standard
VGDC-J16A
16
68
42
165
28
48×48
4-M5
JB919
VGDC-J25A
25
82
55
190
35
58×58
4-M6
VGDC-J32
32
92
64
217
40
68×68
4-M6
VGDC-J40
40
110
70
240
44
80×80
4-M6
VGDC-J50A
50
125
90
285
56
95×95
4-M8
VGDC-J65
65
135
105
315
65
115×115
4-M8
VGDC-J80
80
165
125
358
75
140×140
4-M8
Технические характеристики
Applicable Scope(Pa)