4 voltage input channels 2 inputs for voltage measurement measuring ranges ±40 V, ±120 V, ±400 V, ±1200 V 2 inputs for current measurement via shunt resistors measuring ranges ±80 mV, ±240 mV, ±800 mV, ±2400 mV Signal conditioning linearization, digital filter, average, scaling, min/max storage, RMS, alarm Fast high accuracy digitalization 24 bit ADC, 100 kHz sample rate per channel Galvanic isolation channel to channel to power supply and to interface isolation voltage 1200 VDC / 848 VACrms test voltage 5 kVDC over 1 minute Categories 1000 V CAT II and 600 V CAT III
Технические характеристики
CharacteristicsSignal typedigitalNumber of inputs/outputs4 digital inputs