The Basler Opto Trigger 5 Board provides access to a frame grabbers 8 inputs and 8 outputs. Multiple frame grabbers may be synchronized.
This board has sixteen optically-coupled, galvanically isolated signals for controlling cameras and peripheral devices. The inputs may be configured for single-ended or differential signals, in pull-up or pull-down mode. The outputs may be configured to invert, if preferred.
This board connects to imaWorx, microEnable IV, microEnable 5 marathon, and microEnable 5 ironman frame grabbers via the included 34-pin flat cable. Software license may be required to change the default behavior of each I/O point.
Технические характеристики
Electrical
| Supply Voltage: | 4.5 — 28 VDC |
| Input Threshold: | 20% of Supply Voltage |
| Differential Input Offset: | 10 mV |
| Input Current: | 4 mA per channel |
| Input Propagation Delay: | 40 — 80 ns (60 ns typical) |
| Input Min. Pulse Width: | 200 ns |
| Input Max. Frequency: | 2.5 MHz (50% duty cycle) |
| Output Signal High: | -0.3 VDC of Supply Voltage |
| Output Signal Low: | 0.3 V |
| Output Current: | 20 mA per channel |
| Output Propagation Delay: | 40 — 80 ns (60 ns typical) |
| Output Min. Pulse Width: | 200 ns |
| Output Max. Frequency: | 2.5 MHz (50% duty cycle) |
Miscellaneous
| Encoder Support: | 1 and 2 (quadrature) shaft encoders are supported. |
Connectors
| Internal Connector: | 34-pin box connector (cable included) |
| External I/O Connectors: | 2 x DB15 female |