⟧W2⟧
Specification:
⟧W3⟧⟧W4⟧⟧W5⟧Part Number⟧W6⟧⟧W7⟧1060972⟧W8⟧⟧W9⟧⟧W10⟧⟧W11⟧Mass (measuring wire):⟧W12⟧⟧W13⟧0.58 g/m⟧W14⟧⟧W15⟧⟧W16⟧⟧W17⟧Working temperature range (mechanics):⟧W18⟧⟧W19⟧-30 °C … +70 °C⟧W20⟧⟧W21⟧⟧W22⟧⟧W23⟧Initialization time:⟧W24⟧⟧W25⟧≤ 3 ms ⟧W26⟧⟧W27⟧⟧W28⟧⟧W29⟧Encoder:⟧W30⟧⟧W31⟧Incremental encoders⟧W32⟧⟧W33⟧⟧W34⟧⟧W35⟧Part number mechanic:⟧W36⟧⟧W37⟧5324019⟧W38⟧⟧W39⟧⟧W40⟧⟧W41⟧Mass (including encoder):⟧W42⟧⟧W43⟧230 g⟧W44⟧⟧W45⟧⟧W46⟧⟧W47⟧Relative humidity / Condensation:⟧W48⟧⟧W49⟧90 % (condensation of the optical scanning not permitted)⟧W50⟧⟧W51⟧⟧W52⟧⟧W53⟧Enclosure rating encoder:⟧W54⟧⟧W55⟧IP 65⟧W56⟧⟧W57⟧⟧W58⟧⟧W59⟧Spring return force:⟧W60⟧⟧W61⟧1 N … 1.4 N ⟧W62⟧⟧W63⟧⟧W64⟧⟧W65⟧Mounted mechanic:⟧W66⟧⟧W67⟧MRA-G055-101D4⟧W68⟧⟧W69⟧⟧W70⟧⟧W71⟧EMC:⟧W72⟧⟧W73⟧(according to EN 61000-6-2 and EN 61000-6-4 (class A))⟧W74⟧⟧W75⟧⟧W76⟧⟧W77⟧Working temperature range (combination):⟧W78⟧⟧W79⟧Wird definiert durch den h?heren mininalen und niedrigeren maximalen Wert des Arbeitstemperaturbereichs von Encoder und Mechanik⟧W80⟧⟧W81⟧⟧W82⟧⟧W83⟧Reference signal, number:⟧W84⟧⟧W85⟧Electronically, gated with A and B⟧W86⟧⟧W87⟧⟧W88⟧⟧W89⟧Length of wire pulled out per revolution:⟧W90⟧⟧W91⟧150 mm⟧W92⟧⟧W93⟧⟧W94⟧⟧W95⟧Operating speed:⟧W96⟧⟧W97⟧4 m/s⟧W98⟧⟧W99⟧⟧W100⟧⟧W101⟧Resolution (wire draw + encoder):⟧W102⟧⟧W103⟧0.06 mm ⟧W104⟧⟧W105⟧⟧W106⟧⟧W107⟧Wire acceleration:⟧W108⟧⟧W109⟧10 m/s?⟧W110⟧⟧W111⟧⟧W112⟧⟧W113⟧Maximum load current:⟧W114⟧⟧W115⟧30 mA⟧W116⟧⟧W117⟧⟧W118⟧⟧W119⟧Actual length of cable extension:⟧W120⟧⟧W121⟧1.45 m⟧W122⟧⟧W123⟧⟧W124⟧⟧W125⟧MTTFd: mean time to dangerous failure:⟧W126⟧⟧W127⟧600 a ⟧W128⟧⟧W129⟧⟧W130⟧⟧W131⟧Connection type:⟧W132⟧⟧W133⟧Cable, 8-wire, universal, 1.5 m⟧W134⟧⟧W135⟧⟧W136⟧⟧W137⟧Power consumption:⟧W138⟧⟧W139⟧0.5 W⟧W140⟧⟧W141⟧⟧W142⟧⟧W143⟧Working temperature range (encoder):⟧W144⟧⟧W145⟧-30 °C … +70 °C⟧W146⟧⟧W147⟧⟧W148⟧⟧W149⟧Measuring wire diameter:⟧W150⟧⟧W151⟧0.45 mm⟧W152⟧⟧W153⟧⟧W154⟧⟧W155⟧Housing material, wire draw mechanism:⟧W156⟧⟧W157⟧Plastic, Noryl⟧W158⟧⟧W159⟧⟧W160⟧⟧W161⟧Resistance to shocks:⟧W162⟧⟧W163⟧100 g, 6 ms (according to EN 60068-2-27)⟧W164⟧⟧W165⟧⟧W166⟧⟧W167⟧Mass (mechanics):⟧W168⟧⟧W169⟧80 g⟧W170⟧⟧W171⟧⟧W172⟧⟧W173⟧Resistance to vibration:⟧W174⟧⟧W175⟧20 g, 10 Hz … 2,000 Hz (according to EN 60068-2-6)⟧W176⟧⟧W177⟧⟧W178⟧⟧W179⟧Electrical interface:⟧W180⟧⟧W181⟧4.5 V … 5.5 V, TTL/RS422⟧W182⟧⟧W183⟧⟧W184⟧⟧W185⟧Repeatability:⟧W186⟧⟧W187⟧≤ 0.2 mm ⟧W188⟧⟧W189⟧⟧W190⟧⟧W191⟧Enclosure rating mechanic:⟧W192⟧⟧W193⟧IP 50⟧W194⟧⟧W195⟧⟧W196⟧⟧W197⟧Life of wire draw mechanism:⟧W198⟧⟧W199⟧1 million cycles ⟧W200⟧⟧W201⟧⟧W202⟧⟧W203⟧Pulses per revolution:⟧W204⟧⟧W205⟧2,500⟧W206⟧⟧W207⟧⟧W208⟧⟧W209⟧Maximum output frequency:⟧W210⟧⟧W211⟧300 kHz⟧W212⟧⟧W213⟧⟧W214⟧⟧W215⟧Mounted encoder:⟧W216⟧⟧W217⟧DBS36 Core⟧W218⟧⟧W219⟧⟧W220⟧⟧W221⟧Linearity:⟧W222⟧⟧W223⟧≤ ± 2 mm ⟧W224⟧⟧W225⟧⟧W226⟧⟧W227⟧Supply voltage:⟧W228⟧⟧W229⟧7 V … 30 V⟧W230⟧⟧W231⟧⟧W232⟧⟧W233⟧Reference signal, position:⟧W234⟧⟧W235⟧90 °, electronically, gated with A and B⟧W236⟧⟧W237⟧⟧W238⟧⟧W239⟧Hysteresis:⟧W240⟧⟧W241⟧≤ 0.4 mm ⟧W242⟧⟧W243⟧⟧W244⟧⟧W245⟧Measuring wire material:⟧W246⟧⟧W247⟧Highly flexible stranded steel 1.4401 stainless steel V4A/PA sheathed⟧W248⟧⟧W249⟧⟧W250⟧⟧W251⟧Measuring range:⟧W252⟧⟧W253⟧0 m … 1.25 m⟧W254⟧⟧W255⟧⟧W256⟧⟧W257⟧Part number encoder:⟧W258⟧⟧W259⟧1064245⟧W260⟧⟧W261⟧⟧W262⟧