Diagnostics output: Switching output 2 can be configured as diagnostics output.
Power consumption: Maximum 40 mA at L+ = 24 VDC.
Storage temperature: -20 °C to +80 °C.
Output signal: 2 x PNP/NPN/Push-Pull + 4 mA … 20 mA / 0 V … 10 V.
Shock load: Maximum 30 g, xyz according to IEC 60068-2-27 (11 ms, mechanical shock).
Zero point adjustment: Maximum + 5 % of span.
Electrical safety: Short-circuit protection for QA, Q1, Q2 towards M and L+, protection class III, overvoltage protection 32 V DC, reverse polarity protection L+ towards M.
RoHS certificate: +
Ambient temperature: 0 °C to +60 °C.
Non-repeatability: ≤ ± 0.2 % of span.
Pressure type: Gauge pressure.
Process temperature: 0 °C to +60 °C.
Setting accuracy of switching outputs: ≤ ± 0.2 % of span.
Rated temperature range: +10 °C to +60 °C.
Weight sensor: Approximately 40 g.
Initialization time: 300 ms.
CE-conformity: EMC directive: 2004/108/EC, EN 61326-2-3.
Vibration load: Maximum 5 g (10 … 150 Hz), xyz, according to DIN EN 60068-2-6.
Display: Update rate adjustable (1,000, 500, 200, 100 ms). Pressure display: 4 digits, 16 segments. Pressure units can be switched (bar, MPa, kPa, psi and inHg). LCD with LED backlight (green/red), electronically rotatable by 180°.
Analog signal output and ohmic load RA: Load resistance for voltage output > 3 kOhm, Load resistance for current output.
Housing material: Seals: NBR, Housing: polycarbonate, DIN rail mounting: POM, Buttons: TPE.
Enclosure rating: IP 65 / IP 67 according to IEC 60529.
CRUus certificate: +
Non-linearity: ≤ ± 0.5 % of span (Best Fit Straight Line, BFSL) according to IEC 61298-2.
Accuracy: ≤ ± 1.5 % of span (including non-linearity, hysteresis, zero point and full scale error, corresponds to error of measurement according to IEC 61298-2). ≤ ± 2 % of span including temperature error (including non-linearity, hysteresis, zero point and full scale error, corresponds to error of measurement according to IEC 61298-2).
Relative humidity: ≤ 90 %.
Measuring range: 0 bar … 10 bar.
Gauge pressure ranges: -1 bar … 0 bar; -1 bar … +1 bar; 0 bar … +6 bar; 0 bar … +10 bar.
Process connection: PIF 4 mm + G ?.
Medium: Dry compressed air.
CULus certificate: —
Protection class III: +