Specification:
| Part Number: 1057079 |
| Design: Standard |
| Process connection: G ? A |
| Output signal: 1 PNP transistor output (Q1) and 1 PNP / NPN transistor output (Q2) switchable, 4 mA … 20 mA, 0 V … 10 V automatic switching depending on the load. |
| Ambient temperature operation: -20 °C … +60 °C |
| Lower signal level: 3.8 mA … 4 mA |
| Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono rod probe / rope probe |
| Maximum level change: 500 mm/s |
| Output current: |
| IO-Link: + |
| Measurement: Switch, Continuous |
| Process pressure: -1 bar … 10 bar |
| Conductivity: No limitation |
| Probe type: Mono rod probe |
| Power consumption: ≤ 100 mA at 24 V DC without output load |
| Upper signal level: 20 mA … 20.5 mA |
| Max.probe load: 6 Nm |
| Inactive area at probe end: 10 mm |
| Enclosure rating: IP 67: EN 60529 |
| Probe length: 800 mm |
| EMC: EN 61326-1:2006, 2004/108/EG |
| Capacitive load: 100 nF |
| Signal voltage LOW: ≤ 2 V |
| Output load: 0 V … 10 V > 750 Ohm at Uv >= 14 V, 4 mA … 20 mA 12 V, 4 mA … 20 mA 15 V |
| Inactive area at process connector: 25 mm |
| Process temperature: -20 °C … +100 °C |
| Protection class: III |
| Connection type: Round connector M12 x 1, 5-pin |
| Supply voltage: 12 V DC … 30 V DC |
| Ambient storage temperature: -40 °C … +80 °C |
| Repeatability: ≤ 2 mm |
| Initialization time: ≤ 5 s |
| Resolution: |
| Inductive load: |
| Accuracy of sensor element: ± 5 mm |
| Response time: |
| Hysteresis: Min. 2 mm, free adjustable |
| MTTF: 194.3 a (EN ISO 13849-1) |
| Medium: Fluids |
| Housing material: Plastic PBT |
| Wetted parts: 1.4404, PTFE |
| RoHS certificate: + |
| CULus certificate: + |
| Temperature drift: |
| Signal voltage HIGH: Vs — 2 V |
| GOST approval: + |