Продукт снят с производства производителем. Для замены свяжитесь с менеджером по продажам.
Спецификация:
Supply voltage Vs: DC 18 V … 30 V, limit values
Typ. light spot size (distance): 20 mm (+ 5 x distance in m)
Output current IA: 100 mA
Electromagnetic compatibility (EMC): EN 55011:1998 Kl. B, Gr.1 / EN 61000-6-2
Initialization time: 6 s
Weight: Ca. 1,200 g
Ambient temperature: Operation with cooling case: -10 … +75 °C
Operation: -10 … +55 °C
Storage: -25 … +70 °C
Note: Mechanical aperture
Output time: 1 ms … 4,000 ms
Protection class : III
Aperture delay time: 1 s
Repeatability : 10 mm, 7 mm
Interface for parametrization: RS-232
Switching output : Q1, Q2
Accuracy : ± 10 mm
Mechanical load: Shock: IEC 60068-2-27, -2-29
Sine: IEC 60068-2-6
Average depth: 1/16/64/256/1,024
Cycle time: 1,024 per sec.
Analog output: 4 mA … 20 mA, scalable
Connection type: 1 x cable gland, 1 x Sub-D, 9-pin
Special characteristic: Mechanical aperture
Power consumption : ≤ 6 W
Laser class: 1 (EN 60825-1:Nov.2001, IEC 60825-1:?M2:2001)
Data interface: PROFIBUS DP
Temperature drift : Typ. 0.3 mm/K
Typ. 0.6 mm/K
Enclosure rating: IP 65
Resolution: ≤ 1 mm
Light source: Laser, infrared
Measuring range: 0.5 m … 155 m, 90 % remision
0.5 m … 40 m, 6 % remission
Response time : 1 ms … 4,000 ms