Sick DL100-22AA2110
Datasheet:
- Article: 1066428
- Supply voltage UV: DC. current 18 V … 30 V, Limit values
- Residual ripple: 5 Vss
- Initialization time: Typ. 1.5 s
- Housing material: Metal (Aluminium casting)
- Front window material: Plastic (PMMA)
- Connection type: Connector, M12 compatible, SPEEDCON
- Indication: 6-digit 5 x 7 dot matrix display, LEDs
- Weight: Approx. 800 g (with mounting: 1600 g)
- Current consumption: At 24 V DC
- Dimensions (W x H x D): 69.4 mm x 82.5 mm x 100.2 mm
- Modulation frequency: Fixed
- Protection type: IP65
- Protection class: III
- Measurement range: 0.15 m … 200 m, on Diamond Grade reflective film
- Measurement object: Reflector
- Resolution: 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm
- Reproduction accuracy: 1 mm
- Accuracy: ± 2.5 mm
- Evaluation: 2 ms
- Measurement cycle time: 1 ms
- Output Time: 1 ms
- RADIATION SOURCE: Laser, Red, Visible Red
- Laser Class: 2, Complies with 21 CFR 1040.10 and 1040.11, excluding differences according to “Laser Notice No. 50” of June 24, 2007 (IEC 60825-1:2014, EN 60825-1:2014)
- Typ. light spot size (distance): 5 mm + (2 mm x distance in m)
- Max. travel speed: 15 m/s
- Acceleration (max.): ? 15 m/sІ
- EtherNet/IP: ?
- Multifunction input (MF): 1 x MF1
- Electromagnetic compatibility (EMC): EN 61000-6-2, EN 61000-6-4
- Operating temperature range: –20 °C … +55 ° C , –20 °C … +75 °C, Operation with cooling case ,
- Storage temperature range: –40 °C … +75 °C
- Influence air pressure: 0.3 ppm/hPa
- Temperature influence: 1 ppm/K
- Temperature drift: Typ. 0.1 mm/K
- Typ. Immunity to extraneous light: ? 100.000 lx
- Mechanical strength: Impact: (EN 600 68-2-27), Sine: (EN 600 68-2-6), Noise: (EN 600 68-2 -64),
- Quantity: 2
- Type: Push-pull mode: PNP/NPN
- Function: Distance: switching output for distance
- : Speed: output for speed
- : Maintenance: warning messages about laser aging, when the attenuation value does not reach the required value (for example, when dirty, when the permissible internal temperature of the device is exceeded or under-reached, when the plausibility of the measured value is incorrect, if the laser is not ready for operation, when heating is turned on
- : Laser off
- : Preset
- Maximum output current IA: ? 100 mA
- Category:Long range distance sensors
- Series:Dx100 li>
Connection is via an M12 compatible connector with SPEEDCON. The device features a 6-digit 5 x 7 dot matrix LED display. Its weight is approximately 800 g, or 1600 g with mounting. Current consumption is specified at 24 V DC. The dimensions are 69.4 mm x 82.5 mm x 100.2 mm (W x H x D). The modulation frequency is fixed.
The protection type is IP65, and the protection class is III. The measurement range is from 0.15 m to 200 m on Diamond Grade reflective film, with the measurement object being a reflector. Resolution options include 0.1 mm, 0.125 mm, 1 mm, 10 mm, and 100 mm. Reproduction accuracy is 1 mm, and the overall accuracy is ± 2.5 mm.
Evaluation time is 2 ms, measurement cycle time is 1 ms, and output time is 1 ms. The radiation source is a red visible laser, classified as Class 2, compliant with 21 CFR 1040.10 and 1040.11 (excluding differences per “Laser Notice No. 50”). The typical light spot size is 5 mm + (2 mm x distance in m). Maximum travel speed is 15 m/s, with a maximum acceleration of ? 15 m/sІ. The device supports EtherNet/IP and has 1 multifunction input (MF1).
Electromagnetic compatibility is in accordance with EN 61000-6-2 and EN 61000-6-4. The operating temperature range is –20 °C to +55 °C, or –20 °C to +75 °C with a cooling case. The storage temperature range is –40 °C to +75 °C. Influence of air pressure is 0.3 ppm/hPa, and influence of temperature is 1 ppm/K. Temperature drift is typically 0.1 mm/K. Immunity to extraneous light is ? 100,000 lx.
Mechanical strength is tested for impact (EN 600 68-2-27), sine (EN 600 68-2-6), and noise (EN 600 68-2-64). The quantity is 2. The output type is push-pull mode PNP/NPN. Functions include switching output for distance, output for speed, maintenance warnings (e.g., laser aging, dirt, temperature issues, incorrect measurement plausibility, laser readiness, heating status), laser off, and preset. The maximum output current IA is ? 100 mA. The category is Long range distance sensors, and the series is Dx100.