Specification:
| Part Number | 1207125 |
| External device monitoring (EDM): | + |
| TM (mission time): | 20 a (EN ISO 13849) |
| Response time: | ≤ 14 ms |
| PFHd: | Cascaded systems: 1.3 1E-08 (EN ISO 13849) |
| Switching voltage HIGH: | 24 V DC (VS — 2.25 V DC … VS) |
| Storage temperature: | -25 °C … +70 °C |
| Scanning range: | 0 m … 4 m |
| Restart interlock: | + |
| Safe SICK device communication via EFI/SDL: | — |
| Beam coding: | + |
| Housing material: | Aluminum alloy ALMGSI 0.5 |
| Synchronization: | Optical, without separate synchronization |
| Safety integrity level: | SIL3 (IEC 61508) SILCL3 (EN 62061) |
| Resolution: | 14 mm |
| Housing cross-section (incl. system connection): | 15 mm x 32 mm |
| Power consumption: | ≤ 3 A |
| External device monitoring (delivery status): | Deactivated |
| Protective field height: | 720 mm |
| Vibration resistance: | 5 g, 10 Hz … 55 Hz (EN 60068-2-6) |
| Shock resistance: | 10 g, 16 ms (EN 60068-2-27) |
| Permitted cable length: | ≤ 20 m |
| Conductor cross-section: | 0.34 mm² |
| Protection class: | III (EN 61140) |
| Category: | Category 4 (EN ISO 13849) |
| Display elements: | LEDs |
| Ambient operating temperature: | -20 °C … +55 °C |
| Connection type extension connection: | Female connector M12, 5-pin |
| Weight: | 255 g |
| Connection type: | Male connector M12, 5-pin |
| Supply voltage: | 24 V DC (19.2 V DC … 28.8 V DC) |
| Automatic beam coding: | + |
| Cable length: | 700 mm |
| Air humidity: | 15 % … 95 %, non-condensing |
| Cascaded: | + |
| Ripple: | ≤ 10 % |
| Enclosure rating: | IP 65 (EN 60529) |
| Performance level: | PL e (EN ISO 13849) |
| Configuration method: | Hard wired |
| Integration via Flexi Soft safety controller: | CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET |
| Switching voltage LOW: | 2 V DC |
| Type of output: | PNP semiconductors, short-circuit protected, cross-circuit monitored |
| Safe state in the event of a fault: | At least one OSSD is in the OFF state. |
| Switching current: | 300 mA |
| Type: | Type 4 (IEC 61496) |
| Restart interlock (delivery status): | Deactivated |
| Typical range: | 0 m … 5 m |
The product has part number 1207125. It features external device monitoring (EDM) and TM (mission time) of 20 a (EN ISO 13849). The response time is ≤ 14 ms. PFHd for cascaded systems is 1.3 1E-08 (EN ISO 13849).
The switching voltage HIGH is 24 V DC (VS — 2.25 V DC … VS), and the storage temperature ranges from -25 °C to +70 °C. The scanning range is from 0 m to 4 m. The device includes a restart interlock (+), safe SICK device communication via EFI/SDL (-), and beam coding (+). The housing material is aluminum alloy ALMGSI 0.5. Synchronization is optical, without separate synchronization. The safety integrity level is SIL3 (IEC 61508) and SILCL3 (EN 62061). The resolution is 14 mm.
The housing cross-section, including the system connection, is 15 mm x 32 mm. Power consumption is ≤ 3 A. External device monitoring for delivery status is deactivated. The protective field height is 720 mm. Vibration resistance is 5 g (10 Hz … 55 Hz, EN 60068-2-6), and shock resistance is 10 g (16 ms, EN 60068-2-27). The permitted cable length is ≤ 20 m, with a conductor cross-section of 0.34 mm². The protection class is III (EN 61140), and the category is Category 4 (EN ISO 13849). Display elements are LEDs. The ambient operating temperature is -20 °C to +55 °C.
Connection type for extension connection is a female M12 connector (5-pin). The weight is 255 g. The main connection type is a male M12 connector (5-pin). The supply voltage is 24 V DC (19.2 V DC … 28.8 V DC). Automatic beam coding is enabled (+). The cable length is 700 mm. Air humidity tolerance is 15 % to 95 % (non-condensing). The device supports cascading (+) and has a ripple of ≤ 10 %. The enclosure rating is IP 65 (EN 60529). The performance level is PL e (EN ISO 13849). The configuration method is hard wired. Integration via Flexi Soft safety controller is supported for CANopen, DeviceNet, EtherCAT, EtherNet/IP, Modbus TCP, PROFIBUS DP, PROFINET. The switching voltage LOW is 2 V DC. The type of output is PNP semiconductors, short-circuit protected, and cross-circuit monitored. The safe state in the event of a fault is when at least one OSSD is in the OFF state. The switching current is 300 mA. The type is Type 4 (IEC 61496). Restart interlock for delivery status is deactivated. The typical range is 0 m … 5 m.