Product Description Compact, benchtop design builds on the near flawless 1100 heritage Wide precision flow range of up to 5 mL/min (at 200 bar) High Sensitivity VWD for 190 600 nm &lambda, analysis GMI offers full service agreements & validations on all Agilent HPLC models GMI offers Training & Installation Packages GMI has an fee based applications development department This 1200 Series system, consists of G1312 binary pump G1314 VWD detector G1322 degasser G1330 autosampler G1316 thermostatted column compartment Agilent 1200 Solvent Tray with 2 solvent bottles Computer Data System with NEW Data (Clarity for Windows 10) Analysis Software New 19 Flat Panel Monitor All cables, keyboard, mouse, & complete performance documentation Like the 1100 series the 1200 series model is a workhorse for the demanding needs of any QA/QC lab for the most advanced analytical and method development applications. The heart of any HPLC system is the pump. The 1200 binary pump model G1312 is designed for routine method development and high throughput gradient applications for greatest flexibility with extreme precision for demanding flow requirements such as LC mass spectrometry. Accurate flow rates coupled with low pulsation = awesome The G1315 DAD detector gives you Spectral information from 190 to 950 nm The dual-lamp design and the temperature control of the Agilent 1200 Series diode array detectors ensure outstanding sensitivity. Photodiode arrays with 1024 elements, programmable slit width (1, 2, 4, 8, 16 nm) and the selection of nine different flow cells enable optimization of resolution, linearity and sensitivity&hellip,.it will NOT cramp your analytical capability. The 1200 series autosampler typical repeatability and LACK of carryover is astronomically outstanding. Superior injection precision and lowest carryover makes your runs trustworthy day in day out. The 1200 autosamplers provide for precision levels of <, 0.5 % RSD over an injection volume range from 0.01 &mu,L to 2000 &mu,L. The unique flow-through design, combined with the external needle wash and optional multiple wash solvents, virtually eliminates carryover, even for highly adsorptive compounds. Specifications Agilent 1200 G1311 Series Binary Pump Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve Setable flow range 0.001 5 ml/min, in 0.001 ml/min increments Flow precision 0.07% RSD, or 0.02 min SD whatever is greater Flow accuracy ±, 1% or 10 l/min whatever is greater Pressure Operating range 0 40 MPa (0 400 bar, 0 5880 psi) up to 5 ml/min Operating range 0 20 MPa (0 200 bar, 0 2950 psi) up to 10 ml/min Gradient formation Low pressure quaternary mixing/gradient capability using proprietary high-speed proportioning valve Delay volume 800 1100 l, dependent on back pressure Composition Range 0 95 % or 5 100 %, user selectable Agilent 1200 G1314 VWD Detector 1 signal 13 Hz data rate Wavelength range 190 600 nm Linear absorbance range Greater than 2.5 AU (5 %) at 265 nm Band width 6.5 nm typical Agilent G1316 TCC column compartment Temperature range 10 degrees below ambient to 80 C 10 degrees below ambient to 100 C up to 80 C: flow rates up to 5 ml/min up to 100 C: flow rates up to 2.5 ml/min Column capacity Three 30 cm