| Baumer Article no | 11232078 |
| Type | Distance measuring |
| Measuring distance Sd | 50В …В 550 mm |
| Measuring range Mr | 500 mm |
| Adjustment | Teach-in: button / IO-Link |
| Power on indication | LED green |
| Output indicator | LED yellow |
| Repeat accuracy | 2 … 86 Вµm |
| Linearity error | В± 0.23 % Mr |
| Beam type | Line |
| Temperature drift | 0.08 % Sde/K |
| Light source | Pulsed red laser diode |
| Wave length | 660 nm |
| Laser class | 2 |
| Maximum pulse power | 2 mW |
| Pulse duration | 0.001 … 1.2 ms |
| Pulse period | 0.2 … 3.4 ms |
| Response delay | 0.4 ms |
| Measuring frequency | 5000 Hz |
| Voltage supply range +Vs | 12 … 28 VDC |
| Current consumption max. (no load) | 50 mA |
| Output circuit | Analog and digital |
| Output signal | 0 … 10 VDC / 0 … 5 VDC |
| Load resistance | > 100 kOhm |
| Output current | |
| Short circuit protection | Yes |
| Reverse polarity protection | Yes, Vs to GND |
| Interface | IO-Link V1.1 |
| IO-Link port type | Class A |
| Baud rate | 230.4 kBaud (COM 3) |
| Cycle time | ≥ 1 ms |
| Process data length | 48 Bit |
| Process data structure | Smart Sensor Profile — DMS PDI48.INT32_INT8Bit 0 = SSC1 (distance)Bit 2 = qualityBit 3 = alarmBit 8-15 = scale factorBit 16-47 = 32 Bit measurement |
| Width / diameter | 13.6 mm |
| Height / length | 49 mm |
| Depth | 40.3 mm |
| Type | Rectangular, front view |
| Housing material | Die-cast zinc |
| Front (optics) | Glass |
| Connection types | Connector M8 4 pin |
| Weight | 67 g |
| Ambient light immunity | |
| Protection class | IP 67 |
| Operating temperature | -10 … +50 °C |
| Storage temperature | -20 … +60 °C |
| Vibration (sinusoidal) | IEC 60068-2-6:20081 mm p-p at f = 10 — 55 Hz, duration 5 min per axis30 min endurance at f = 55 Hz per axis |
| Shock (semi-sinusoidal) | IEC 60068-2-27:200930 g / 11 ms, 6 jolts per axis and direction |
This is a distance measuring device with article number 11232078. The device has a measuring distance (Sd) from 50 to 550 mm and a measuring range (Mr) of 500 mm. Adjustment can be done via a button or IO-Link. Power on is indicated by a green LED, and output is indicated by a yellow LED.
The repeat accuracy is 2 to 86 µm, with a linearity error of ±0.23 % Mr. The beam type is a line. The temperature drift is 0.08 % Sde/K. The light source is a pulsed red laser diode with a wavelength of 660 nm and laser class 2. Maximum pulse power is 2 mW, with a pulse duration of 0.001 to 1.2 ms and a pulse period of 0.2 to 3.4 ms. The response delay is 0.4 ms, and the measuring frequency is 5000 Hz.