Additional Features:
- Distortion measurement range: any fundamental frequency, 5 Hz to 600 kHz
- Distortion levels of 0.1%-100% are measured full scale in 7 ranges
- Elimination characteristics: Fundamental rejection >, 80 dB. Second harmonic accuracy for a fundamental of 5 to 20 Hz, better than +1 dB, 20 Hz to 20 kHz: better than ±0.6 dB, 20 kHz to 100 kHz: better than -1 dB, 100 kHz to 300 kHz: better than -2 dB, 300 kHz to 600 kHz: better than -3 dB
- Distortion introduced by instrument: >,-70 dB (0.03%) from 5 Hz to 200 kHz, 64 dB (0.6%) from 200 kHz to 600 kHz. Meter indication is proportional to average value of a sine wave
- Frequency calibration accuracy: better than ±5% from 5 Hz to 300 kHz. Better than ±10% from 300 to 600 kHz
- Input Impedance: distortion mode, 1 MΩ ±5% Shunted by <,70pF (10 MΩ shunted by <,10 pF with HP 10001A 10,1 divider probe
- Voltmeter mode: 1MΩ ±5% shunted by <,35 pF 1 to 300 V rms, 1 MΩ ±5 % shunted by <,70 pF, 300 µV to 0.3 V rms
- Input level for distortion measurements: 0.3 V rms for 100% set level or 0.245 V for 0 dB set level (up to 300 V may be attenuated to set level reference)
- DC Isolation: signal ground may be +/- 400 V dc from external chassis
- Voltmeter range: 300 µV to 300 V rms full scale (13 ranges) 10 dB per range
- Noise measurements: voltmeter residual noise on the 300 µV range: <,25 µV rms, when terminated in 600 (shielded) ohms, <,30 µV rms terminated with a shielded 100Ω resistor
- Output: 0.1 ±0.01 V rms open circuit and 0.05 ±0.005 V rms into 2 kΩ for full scale meter deflection
- Output Impedance: 2 kΩ
- Power supply: 115 or 230 V ±10%, 50 to 66 Hz, approximately 4 VA
- AM Detector: high impedance DC restoring peak detector with semi-conductor diode operates from 550 kHz to greater than 65 MHz. Broadband input, no tuning is required
- Maximum input: 40 V p-p AC or 40 V peak transient
- Distortion introduced by detector: carrier frequency: 550 kHz-1.6 MHz: <,50 Db (0.3%) for 3-8 V rms carriers modulated 30%. 1.6MHz-65 MHz: <,40 dB (1%) for 3-8 V rms carriers modulated 30%
The Agilent 332A Distortion Analyzer is a solid-state instrument for measuring distortion and ac voltages. The 332A includes a high impedance AM detector which operates from 550 kHz to greater than 65 MHz. Distortion levels of 0.1% to 100% full scale are measured in seven ranges for any fundamental frequency from 5 Hz to 600 kHz., harmonics are indicated up to 3 MHz. The high sensitivity of these instruments requires only 0.3 V rms for the 100% set level reference. An output is provided at the OUTPUT connectors for monitoring the distortion with an oscilloscope, a true rms voltmeter, or a wave analyzer. The instruments are capable of a dc isolation voltage of 400 volts above chassis ground.
The transistorized voltmeter contained in the 332A can be used separately for general purpose voltage and gain measurements. The voltmeter has a frequency range of 5 Hz to 3 MHz (20 Hz to 500 kHz for 300 µV range) and a voltage range of 300 µV to 300V rms full scale.
The AM detector included in the 332A is a broadband dc restoring peak detector consisting of a semiconductor diode and filter circuit. AM distortion levels as low as 0.3% can be measured on a 3 V to 8 V rms carrier modulated 30% in the standard broadcast band, and lower than 1% distortion can be measured at the same level of the carrier up to 65 MHz.
Технические характеристики
| Manufacturer | Agilent, HP, Keysight |
|---|---|
| Condition | Used |
| Frequency | 600 kHz |