Поставка оптоэлектронных компонентов ведущих мировых производителей

Amerex HV-серия

Доставка импортных компонентов Amerex Instruments по России от 3х недель транспортными компаниями СДЭК, Деловые Линии, Major Express.
Оплата физическими и юридическими лицами безналичным расчетом.
Цена может измениться после запроса у поставщика!
Артикул: 8021-10-0001 TME арт.: 8021-10-0001

Product Description Space-saving design with lid opening upward. Programmable auto-start for initiating a cycle up to 1 week later. Dual-sensing lid interlock prevents lid opening when chamber is pressurized or when temperature exceeds 97C. Automatic air purging by a microprocessor prevents over-pressurization during a cycle. One-touch lever to easily open and close chamber lid. Programmable rate of steam exhaust. Door-closure sensor provides a prompt and the cycle will not start unless the door is closed properly. In-process display shows status and progress of sterilization cycle. Agar sterilization mode for sterilizing agar and then automatically maintaining it at liquid temperature. Unique accessory: Floating sensor to monitor load temperature. Sterilization timer is activated only when load temperature reaches set temperature. Agar melting mode for rapidly melting agar and maintaining it at liquid temperature, or for a hot and faster start-up Memory backup system retains user-programmed parameters even in case of power failure. Technical Specifications HV-25 AND HV-50 SPECIFICATIONS MODEL HV-25 HV-50 TEMPERATURE Operating Range 105C to 126C 105C to 135C Display Range 128C 137C Warming Range 45C to 60C Agar Dissolution Heating at 60C to 100C for up to 1 hour (temperature and time programmable), followed by 45C to 60C (programmable for up to 20 hours to prevent coagulation) GAUGE PRESSURE Operating Range 3 to 22 psi gauge (0.02 to 148MPa) 3 to 30 psi (0.02 to 0.206MPa) Maximum Allowable 27 psi (0.186MPa) 38 psi (0.26MPa) TIMER Sterilization 1 to 250 minutes Delayed Auto-start Program autoclave to start 1 minute to 7 days later DIMENSIONS Overall (W x D x H) 19.0 x 18.0 x 37.4 (48 cm x 46 cm x 95 cm) 20 x 21 x 41 (51 cm x 53 cm x 104 cm) Chamber (Diameter x Height) 25 liters 9.4 x 21.6 (24 cm x 55 cm) 50 liters 11.8 x 28.0 (30 cm x 71 cm) SAFETY DEVICES Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker PROGRAMS 1. For agar Heating -&gt, Sterilization -&gt, Exhaust (from no exhaust to slow, programmable) -&gt, Warming -&gt, Completion 2. For liquids Heating -&gt, Sterilization -&gt, Exhaust (from no exhaust to slow, programmable) -&gt, Completion 3. For solids Heating -&gt, Sterilization -&gt, Exhaust (fast, default) -&gt, Completion 4. For melting agar or for faster start-up Rapid melting at 60C to 100C (temperature and time programmable) -&gt, Maintain at 45C to 60C (temperature programmable) -&gt, Completion ACCESSORIES Stainless steel Mesh wire baskets, buckets (pails), and round test tube racks Factory or field installed Floating (load) sensor, digital printer, and data logger POWER Source 120V, 50/60 Hz (220V/240V available) Consumption 1500 watts (1500VA) 2000 watts (2000VA) SHIPPING WEIGHT 160 lb (73 kg) 180 lb (82 kg) WARRANTY: Autoclaves are protected by a 12-month warranty. HV-85 AND HV-110 SPECIFICATIONS MODEL HV-85 HV-110 TEMPERATURE Operating Range 105C to 135C Display Range 137C Warming Range 45C to 60C Agar Dissolution Heating at 60C to 100C for up to 1 hour (temperature and time programmable), followed by 45C to 60C (programmable for up to 20 hours to prevent coagulations) GAUGE PRESSURE Operating Range 3 to 30 psi (0.021 to 0.206MPa) Maximum Allowable 38 psi ( 0.26MPa) TIMER Sterilization 1 to 250 minutes Delayed Auto-start Program autoclave to start 1 minute to 7 days later DIMENSIONS Overall (W x D x H) 26.0 x 25.6 x 39.4 (66 cm x 65 cm x 100 cm) 26.0 x 25.6 x 46.5 (66 cm x 65 cm x 118 cm) Chamber (Diameter x Height) 85 liters 16.5 x 24.2 (42.0 cm x 61.5 cm) 110 liters 16.5 x 31.3 (42.0 cm x 79.5 cm) SAFETY DEVICES Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker PROGRAMS 1. For agar Heating -&gt, Sterilization -&gt, Exhaust (from no exhaust to slow, programmable) -&gt, Warming -&gt, Completion 2. For liquids Heating -&gt, Sterilization -&gt, Exhaust (from no exhaust to slow, programmable) -&gt, Completion 3. For solids Heating -&gt, Sterilization -&gt, Exhaust (fast, default) -&gt, Completion 4. For melting agar or for faster start-up Rapid melting at 60C to 100C (temperature and time programmable) -&gt, Maintain at 45C to 60C (temperature programmable) -&gt, Completion ACCESSORIES Stainless steel Mesh wire baskets, buckets (pails), and round test tube rack Factory or field installed Floating (load) sensor, digital printer, and data logger POWER Source 208V/220V/240V, 50/60 Hz, single phase Consumption 3000 watts (3000VA) 4000 watts (4000VA) SHIPPING WEIGHT 282 lb (128 kg) 308 lb (140 kg) WARRANTY: Autoclaves are protected by a 12-month warranty.

Технические характеристики

Technical SpecificationsHV-25 AND HV-50 SPECIFICATIONS

MODEL HV-25 HV-50
TEMPERATURE
Operating Range 105ºC to 126ºC 105ºC to 135ºC
Display Range 128ºC 137ºC
Warming Range 45ºC to 60ºC
Agar Dissolution Heating at 60ºC to 100ºC for up to 1 hour (temperature and time programmable), followed by 45ºC to 60ºC
(programmable for up to 20 hours to prevent coagulation)
GAUGE PRESSURE
Operating Range 3 to 22 psi gauge (0.02 to 148MPa) 3 to 30 psi (0.02 to 0.206MPa)
Maximum Allowable 27 psi (0.186MPa) 38 psi (0.26MPa)
TIMER
Sterilization 1 to 250 minutes
Delayed Auto-start Program autoclave to start 1 minute to 7 days later
DIMENSIONS
Overall (W x D x H) 19.0′ x 18.0′ x 37.4′
(48 cm x 46 cm x 95 cm)
20′ x 21′ x 41′
(51 cm x 53 cm x 104 cm)
Chamber
(Diameter x Height)
25 liters
9.4′ x 21.6′ (24 cm x 55 cm)
50 liters
11.8′ x 28.0′ (30 cm x 71 cm)
SAFETY DEVICES Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker
PROGRAMS
1. For agar Heating -&gt, Sterilization -&gt, Exhaust (from no exhaust to slow, programmable) -&gt, Warming -&gt, Completion
2. For liquids Heating -&gt, Sterilization -&gt, Exhaust (from no exhaust to slow, programmable) -&gt, Completion
3. For solids Heating -&gt, Sterilization -&gt, Exhaust (fast, default) -&gt, Completion
4. For melting agar or for faster start-up Rapid melting at 60°C to 100°C (temperature and time programmable) -&gt, Maintain at 45°C to 60°C (temperature programmable) -&gt, Completion
ACCESSORIES
Stainless steel Mesh wire baskets, buckets (pails), and round test tube racks
Factory or field installed Floating (load) sensor, digital printer, and data logger
POWER
Source 120V, 50/60 Hz (220V/240V available)
Consumption 1500 watts (1500VA) 2000 watts (2000VA)
SHIPPING WEIGHT 160 lb (73 kg) 180 lb (82 kg)

WARRANTY: Autoclaves are protected by a 12-month warranty.

HV-85 AND HV-110 SPECIFICATIONS

MODEL HV-85 HV-110
TEMPERATURE
Operating Range 105ºC to 135ºC
Display Range 137ºC
Warming Range 45ºC to 60ºC
Agar Dissolution Heating at 60ºC to 100ºC for up to 1 hour (temperature and time programmable), followed by 45ºC to 60ºC
(programmable for up to 20 hours to prevent coagulations)
GAUGE PRESSURE
Operating Range 3 to 30 psi (0.021 to 0.206MPa)
Maximum Allowable 38 psi ( 0.26MPa)
TIMER
Sterilization 1 to 250 minutes
Delayed Auto-start Program autoclave to start 1 minute to 7 days later
DIMENSIONS
Overall (W x D x H) 26.0′ x 25.6′ x 39.4′
(66 cm x 65 cm x 100 cm)
26.0′ x 25.6′ x 46.5′
(66 cm x 65 cm x 118 cm)
Chamber
(Diameter x Height)
85 liters
16.5′ x 24.2′ (42.0 cm x 61.5 cm)
110 liters
16.5′ x 31.3′ (42.0 cm x 79.5 cm)
SAFETY DEVICES Dual-sensing lid interlock, over-pressure power cutoff, over-temperature power cutoff, low-water power cutoff, mechanical pressure relief valve, microprocessor-controlled pressure relief valve, lid-closure detector, over-current detector and circuit breaker
PROGRAMS
1. For agar Heating -&gt, Sterilization -&gt, Exhaust (from no exhaust to slow, programmable) -&gt, Warming -&gt, Completion
2. For liquids Heating -&gt, Sterilization -&gt, Exhaust (from no exhaust to slow, programmable) -&gt, Completion
3. For solids Heating -&gt, Sterilization -&gt, Exhaust (fast, default) -&gt, Completion
4. For melting agar or for faster start-up Rapid melting at 60°C to 100°C (temperature and time programmable) -&gt, Maintain at 45°C to 60°C (temperature programmable) -&gt, Completion
ACCESSORIES
Stainless steel Mesh wire baskets, buckets (pails), and round test tube rack
Factory or field installed Floating (load) sensor, digital printer, and data logger
POWER
Source 208V/220V/240V, 50/60 Hz, single phase
Consumption 3000 watts (3000VA) 4000 watts (4000VA)
SHIPPING WEIGHT 282 lb (128 kg) 308 lb (140 kg)

WARRANTY: Autoclaves are protected by a 12-month warranty.