Amerex HG-серия

Доставка импортных компонентов Amerex Instruments по России от 3х недель транспортными компаниями СДЭК, Деловые Линии, Major Express.
Оплата физическими и юридическими лицами безналичным расчетом.
Цена может измениться после запроса у поставщика!
Артикул: 8021-10-0004 TME арт.: 8021-10-0004

Product Description The HG-Series include 4 models with innovative features and functions. The chamber diameter of the HG-50 and HG-80 is 14.3 (36.4 cm) while the chamber diameter of the larger HG-113 and HG-133 is 19.7 (50.0 cm). Features and functions include the following: Automatic Lid Opening Button replaces a foot pedal. Automatic Lid Closing Button closes lid conveniently and safely. Safety Interlock senses pressure and temperature and prevents lid from opening during a cycle, when the chamber is pressurized, and when the high temperature can cause boil over. Programmable Auto-Start for running a cycle from 1 to 99 hours later. Large (15 liters) / Efficient Steam Condenser ensures no steam exhausts into the lab. The HG-113 and HG-133 incorporate a radiator for this. Over-Flow Lamp indicates that the drain bottle is full and ready to be emptied. Built-in Cooling Fan for faster post-sterilization cooling and shorter completion time. Selectable Rate of steam venting after sterilization. Programmable Time for air removal before sterilization. Twelve Programs Cycles can be stored. Large Control and Display Panel improves functionality and shows the progress of the sterilization cycle. Technical Specifications HG-50 AND HG-80 SPECIFICATIONS MODEL HG-50 HG-80 Overall (W x D x H) 19.7 x 27.2 x 35.0 (45.5 cm x 69.1 cm x 89.0 cm) 19.7 x 27.2 x 40.6 (45.5 cm x 69.1 cm x 103.0 cm) Chamber (Diameter x Height) 50 liters 14.3 x 19.0 (36.4 cm x 48.2 cm) 76 liters 14.3 x 28.7 (36.4 cm x 73.0 cm) Temperature Range 105C to 135C Sterilization Timer 1 to 300 minutes Agar Warming Range After sterilization, agar can be maintained from 45C to 60C (programmable) for up to 24 hours to prevent coagulation Delayed Auto-Start Program autoclave to start 1 to 99 hours later Cooling Fan Switch to turn fan on or off Air Removal Timer Programmable, 3 to 9 minutes after temperature has reached 97C Steam Venting Selectable from: No venting and three other venting rates Temperature for Release of Lid Interlock Programmable, 60C to 97C for greater safety and flexibility Sterilization Program Cycles 1) Liquid cycle, 2) Agar (liquid with warming) cycle, and 3) Solid cycle Additional Cycles for Agar Dissolution Cycle for dissolving and keeping agar warm (no sterilization) Agar Dissolution Protocol Initially at 60C-100C for 1-60 min., then at 45C-60C for up to 24 hrs. Safety Features Circuit breaker with GFCI, low-water power cut-off, over-temp power cutoff, over-pressure power cut-off, safety valve, sensor for improper lid closing Steam Condenser 15-liter water tank Drain Water Bottle 2 liters Power Requirements 120V or 220V, 50/60 Hz, single phase 220V, 50/60 Hz, single phase Power Consumption 2.0kW, optional 3.0kW for 220V only 3.8 kW Shipping Weight 180 lb (82 kg) 255 lb (116 kg) HG-113 AND HG-133 SPECIFICATIONS MODEL HG-113 HG-133 Overall (W x D x H) 27.0 x 34.3 x 36.6 (68.6 cm x 87.0 cm x 93.0 cm) 27.0 x 34.3 x 40.7 (68.6 cm x 87.0 cm x 103.4 cm) Chamber (Diameter x Height) 108 liters 19.7 x 21.7 (50.0 cm x 55.2 cm) 129 liters 19.7 x 25.8 (50.0 cm x 65.6 cm) Temperature Range 105C to 135C Sterilization Timer 1 to 300 minutes Agar Warming Range After sterilization, agar can be maintained from 45C to 60C (programmable) for up to 24 hours to prevent coagulation Delayed Auto-Start Program autoclave to start 1 hour to 99 hours later Cooling Fan Switch to turn fan on or off Air Removal Timer Programmable, 3 to 9 minutes after temperature has reached to 97C Steam Venting Selectable from: No venting and three other venting rates Temperature for Release of Lid Interlock Programmable, 60C to 97C for greater safety and flexibility Sterilization Program Cycles 1) Liquid cycle, 2) Agar (liquid with warming) cycle, and 3) Solid cycle Additional Cycles for Agar Dissolution Cycle for dissolving and keeping agar warm (no sterilization) Agar Dissolution Protocol Initially at 60C-100C for 1-60 minutes, then at 45C to 60C for up to 24 hrs. Safety Features Circuit breaker with GFCI, low-water power cut-off, over-temp power cutoff, over-pressure power cut-off, safety valve, sensor for improper lid closing Steam Condenser Radiator Drain Water Bottle 8 liters Power Requirements 3-phase, 400VAC (other 3-phase voltages available) Power Consumption 5.7kW @ 400VAC Shipping Weight 310 lb (140 kg) 330 lb (150 kg)

Технические характеристики

Technical SpecificationsHG-50 AND HG-80 SPECIFICATIONS

MODEL HG-50 HG-80
Overall (W x D x H) 19.7′ x 27.2′ x 35.0′
(45.5 cm x 69.1 cm x 89.0 cm)
19.7′ x 27.2′ x 40.6′
(45.5 cm x 69.1 cm x 103.0 cm)
Chamber
(Diameter x Height)
50 liters
14.3′ x 19.0′ (36.4 cm x 48.2 cm)
76 liters
14.3′ x 28.7′ (36.4 cm x 73.0 cm)
Temperature Range 105°C to 135°C
Sterilization Timer 1 to 300 minutes
Agar Warming Range After sterilization, agar can be maintained from 45°C to 60°C (programmable) for up to 24 hours to prevent coagulation
Delayed Auto-Start Program autoclave to start 1 to 99 hours later
Cooling Fan Switch to turn fan on or off
Air Removal Timer Programmable, 3 to 9 minutes after temperature has reached 97°C
Steam Venting Selectable from: No venting and three other venting rates
Temperature for Release of Lid Interlock Programmable, 60°C to 97°C for greater safety and flexibility
Sterilization Program Cycles 1) Liquid cycle, 2) Agar (liquid with warming) cycle, and 3) Solid cycle
Additional Cycles for Agar Dissolution Cycle for dissolving and keeping agar warm (no sterilization)
Agar Dissolution Protocol Initially at 60°C-100°C for 1-60 min., then at 45°C-60°C for up to 24 hrs.
Safety Features Circuit breaker with GFCI, low-water power cut-off, over-temp power cutoff, over-pressure power cut-off, safety valve, sensor for improper lid closing
Steam Condenser 15-liter water tank
Drain Water Bottle 2 liters
Power Requirements 120V or 220V, 50/60 Hz, single phase 220V, 50/60 Hz, single phase
Power Consumption 2.0kW, optional 3.0kW for 220V only 3.8 kW
Shipping Weight 180 lb (82 kg) 255 lb (116 kg)

HG-113 AND HG-133 SPECIFICATIONS

MODEL HG-113 HG-133
Overall (W x D x H) 27.0′ x 34.3′ x 36.6′
(68.6 cm x 87.0 cm x 93.0 cm)
27.0′ x 34.3′ x 40.7′
(68.6 cm x 87.0 cm x 103.4 cm)
Chamber
(Diameter x Height)
108 liters
19.7′ x 21.7′ (50.0 cm x 55.2 cm)
129 liters
19.7′ x 25.8′ (50.0 cm x 65.6 cm)
Temperature Range 105°C to 135°C
Sterilization Timer 1 to 300 minutes
Agar Warming Range After sterilization, agar can be maintained from 45°C to 60°C (programmable) for up to 24 hours to prevent coagulation
Delayed Auto-Start Program autoclave to start 1 hour to 99 hours later
Cooling Fan Switch to turn fan on or off
Air Removal Timer Programmable, 3 to 9 minutes after temperature has reached to 97°C
Steam Venting Selectable from: No venting and three other venting rates
Temperature for Release of Lid Interlock Programmable, 60°C to 97°C for greater safety and flexibility
Sterilization Program Cycles 1) Liquid cycle, 2) Agar (liquid with warming) cycle, and 3) Solid cycle
Additional Cycles for Agar Dissolution Cycle for dissolving and keeping agar warm (no sterilization)
Agar Dissolution Protocol Initially at 60°C-100°C for 1-60 minutes, then at 45°C to 60°C for up to 24 hrs.
Safety Features Circuit breaker with GFCI, low-water power cut-off, over-temp power cutoff, over-pressure power cut-off, safety valve, sensor for improper lid closing
Steam Condenser Radiator
Drain Water Bottle 8 liters
Power Requirements 3-phase, 400VAC (other 3-phase voltages available)
Power Consumption 5.7kW @ 400VAC
Shipping Weight 310 lb (140 kg) 330 lb (150 kg)