Product Description SMALLER VOLUME, HIGH PRODUCTIVITY The ARCHITECT ci4100 combines ARCHITECT c4000 and ARCHITECT i1000SR instruments offering lower volume laboratories the enhanced efficiency and productivity employed by larger volume laboratories. The ARCHITECT ci4100 offers a maximum throughput of up to 900 tests per hour, including 800 clinical chemistry and 100 immunoassay tests. Featuring a load-up capacity of 180 samples with 35 priority positions, the ARCHITECT ci4100 has up to 115 refrigerated reagent positions plus Integrated Chip Technology (Na+, K+ and Cl-). For in vitro diagnostic use only. One-Year Warranty SPECIFICATIONS Methods See c4000 and i1000SR specifications Maximum Throughput Up to 900 tests/hour Sample Types See c4000 and i1000SR specifications Sample Tubes Height: 72-102 mm Diameter 9.6-16.1 mm Sample Cup Yes (50 L dead volume) Sample Capacity 180 Sample Barcode Types Code 39, Codabar, Interleaved 2 of 5, Code 128 Sample Result Storage 50,000 Sample Volume See c4000 and i1000SR specifications Automatic Dilution Yes Sample Probe Carryover &le,0.1 parts per million Reagent Capacity Up to 115 refrigerated positions plus patented ISE (Na+, K+ and Cl-) Reagent Type See c4000 and i1000SR specifications Reagent Onboard Stability See c4000 and i1000SR specifications Calibration Frequency See c4000 and i1000SR specifications Sample, Clot, and Bubble Detection Yes Reagent Pressure Monitoring See c4000 and i1000SR specifications Sample Interference Measurement Yes: Hemolysis, Icterus, and Lipemia System Control Center 1 SCC, with color touchscreen monitor, keyboard and mouse Onboard Maintenance Records Yes Online Error Code Help Yes Host Interface Bidirectional, serial RS-232 interface, host query option available Remote Diagnostics AbbottLink Dimensions (H x W x D) 49 x 111 x 36 125.1 x 281.2 x 90.7 cm Weight 1,677 lbs 760.7 kg Electrical Requirements See c4000 and i1000SR specifications Water Requirements See c4000 and i1000SR specifications Heat Output* See c4000 and i1000SR specifications Sample Loading RSH *Values provided represent the typical output in Running mode for the system processing module and sample handler. A maximum value of 389 BTU/hr was obtained for the System Control Center (SCC) using the ARCHITECT i2000SR as a representative system. Values obtained during an internal study. Data is on file with Abbott. Note: Some of these specifications are based on the combination of the ARCHITECT c4000 and the ARCHITECT i1000SR. For accurate and complete specifications, please refer to the individual operations manual.