The 117 is a 3.5 digit handheld multimeter from Fluke. A multimeter is an instrument used to test and measure alternating current (AC) or direct current (DC) voltage, resistance, and electric current. Multimeters combine voltmeters, ammeters, and ohmmeters. Electricians use multimeters to run diagnostics on batteries, switches, components, power sources, and motors.

Доставка импортных компонентов по России от 3х недель транспортными компаниями СДЭК, Деловые Линии, Major Express.
Оплата физическими и юридическими лицами безналичным расчетом.
Цена может измениться после запроса у поставщика!
Артикул: 117 Fluke Multimeter TME арт.: 117 Fluke Multimeter

Technical Data

Fluke 117

Electrician’s Multimeter

with Non-Contact Voltage

Features include:

VoltAlert

technology for non-contact voltage detection

AutoVolt automatic ac/dc voltage selection

LoZ: helps prevent false readings due to ghost voltage

Large white LED backlight to work in poorly lit areas

True-rms for accurate measurements on non-linear loads

Measures 10 A (20 A overload for 30 seconds)

Resistance, continuity, frequency and capacitance

Min/Max/Average to record signal fluctuations

Compatible with optional magnetic hanger (ToolPak

) for

hands free operation

CAT III 600 V safety rated

Compact true-rms meter for
commercial applications

The Fluke 117 is the ideal meter for
demanding settings like commercial
buildings, hospitals and schools. The 117
includes integrated non-contact voltage
detection to help get the job done faster.



General specifications

Accuracy is specified for 1 year after calibration, at operating
temperatures of 18 °C to 28 °C, with relative humidity at
0 % to 90 %.
The accuracy specifications take the form of:
± ( [ % of reading ] + [ counts ] )



Maximum voltage between any
terminal and earth ground

600 V

Surge protection

6 kV peak per IEC 61010-1 600 V
CAT III, Pollution Degree 2

Fuse for A input

11 A, 1000 V FAST Fuse
(Fluke PN 803293)

Display

Digital: 6,000 counts, updates 4/sec

Bar graph

33 segments, updates 32/sec

Operating temperature

-10 °C to + 50 °C

Storage temperature

-40 °C to + 60 °C

Battery

9 volt Alkaline, NEDA 1604A/
IEC 6LR61

Battery life

400 hours typical, without backlight

N10140

R

Actual size

Accuracy Specifications

Measurement

Range

Resolution

Accuracy

± ([% of reading] + [counts])

DC millivolts

600.0 mV

0.1 mV

0.5 % + 2

DC volts

6.000 V

0.001 V

0.5 % + 2

60.00 V

0.01 V

600.0 V

0.1 V

Auto volts

600.0 V

0.1 V

2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)

AC millivolts

1

true-rms

600.0 mV

0.1 mV

1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)

AC volts

1

true-rms

6.000 V

0.001 V

1.0 % + 3 (45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)

60.00 V

0.01 V

600.0 V

0.1 V

Continuity

600 Ω

1 Ω

Beeper on &lt, 20 Ω off &gt, 250 Ω, detects

opens or shorts of 500 µs or longer.

Ohms

600.0 Ω

0.1Ω

0.9 % + 2

6.000 kΩ

0.001 kΩ

0.9 % + 1

60.00 kΩ

0.01 kΩ

600.0 kΩ

0.1 kΩ

6.000 MΩ

0.001 MΩ

40.00 MΩ

0.01 MΩ

1.5 % + 2

Diode test

2.000 V

0.001 V

0.9 % + 2

Capacitance

1000 nF

1 nF

1.9 % + 2

10.00 µF

0.01 µF

100.0 µF

0.1 µF

9999 µF

1 µF

100 µF to 1000 µF

1.9 % + 2

&gt, 1000 µF

5 % + 20

Lo-Z capacitance

1 nF to 500 µF

10 % + 2 typical

AC amps true-rms
(45 Hz to 500 Hz)

6.000 A

0.001 A

1.5 % + 3

10.00 A

0.01 A

20 A overload for 30 seconds max.

DC amps

6.000 A

0.001 A

1.0 % + 3

10.00 A

0.01 A

20 A overload for 30 seconds max.

Hz (V or A input)

2

99.99 Hz

0.01 Hz

0.1 % + 2

999.9 Hz

0.1 Hz

9.999 kHz

0.001 kHz

50.00 kHz

0.01 kHz

Notes:

1

All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-
zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of ≤ 3

at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled.

2

Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.

Ordering
Information

Fluke-117

Electrician’s
Multimeter with
Non-Contact Voltage

Included

TL75 Test leads, holster, User’s
manual and 9 V battery (installed).

Технические характеристики

ManufacturerFluke
ConditionNew
AC Voltage600 V
DC Voltage600 V
Resolution3.5
TypeHandheld